Daikin heat pump fault codes
Daikin Altherma codes come in two forms depending on how old your controller is, and the difference matters — U4 and U4-00 are the same family, but 7H-01 and 7H-08 are different jobs. Daikin also state plainly that clearing these is a job for your installer rather than for you.
Where the code shows on a Daikin
Daikin print an Altherma code in two parts, an error code and a detailed error code, and the controller shows them together: 7H-01, U4-00, E3-24. The first part is the fault family and the second narrows the cause, so looking up only the first half against an old two-character list will give you the wrong component. The two-part form is in Daikin’s installer guides from at least 2018 and on every Altherma 3 controller; the bare form, U4 or E7 or H3, is what Daikin UK’s own owner leaflet describes as "typically a number and a letter, for example 7H" and what older displays show. Every Altherma 3 controller also tells you the meaning in words: open the main menu with the left dial, go to Malfunctioning, and it gives a short description with the code, then a long one. Two more cues. Where the description begins "OU:", Daikin mean the fault is in the outdoor unit, which in most cases puts it in the refrigerant or inverter side and out of reach of anyone without F-Gas certification. And Daikin’s air conditioners use the same two-character vocabulary, so some codes — U0, U4, A5 — appear in both tables with different systems behind them. If your Daikin is a wall-mounted air conditioner rather than an Altherma with radiators or a cylinder, the pages in our air-conditioning section are the ones for you.
How to reset a Daikin
Daikin’s position is consistent across their documents: the installer reference guide says it is important to understand the problem and take measures before resetting an error code, and that this should be done by a licensed installer or by your local dealer; Daikin UK’s technical support page tells owners who see an error code to contact their certified installer right away. Behind that, the service manual gives every code one of three reset classes, and the pages here quote them. "Automatic reset" codes clear themselves once the condition passes, and Daikin publish 7H-01, 7H-07, 7H-08, 89-02, 89-03, AH-00, C0-01, U0-00 and U5-00 in that class. "Manual reset via user interface" codes stay until someone resets them on the controller, and the installer guide notes that the user interface itself displays how; 7H-04, 7H-05, 7H-06, 89-01, A5-00, C0-00, C0-02, E3-00 and E7-00 are in that class. "Power reset via outdoor unit" codes — U4-00 among them — need the outdoor unit’s supply cycled. Daikin UK’s older owner leaflet for the Altherma LT split does give an owner reset: turn the power off, wait 60 seconds, turn it back on, and if the code returns, note it and call. Two things to establish before treating anything as urgent: whether the home screen shows an error or a malfunction, since Daikin distinguish the two by severity, and whether you actually have heat, since several codes are annotated as warnings and the unit keeps running through them.
Most common Daikin faults
The Daikin codes people look up most.
- Bill has jumpedGet it checkedThe most important heat pump fault has no code. If your electricity cost has stepped up with no change in habits, the backup heater is probably doing the work.
- Ice on the outdoor unitGet it checkedNormal in cold damp weather, and the unit clears it itself. Daikin specifically forbid helping — no hot water, no de-icer, no scraping.
- 7HGet it checkedA water flow problem. The sub-code matters more than the code: 7H-01 clears itself, 7H-04 to 7H-06 need a manual reset, 7H-08 is the pump, and 7H-07 is the unit freeing a stuck pump.
- Water at the tap is too coldGet it checkedDaikin give two causes and a remedy that costs money. Before using it, check what your schedule is actually asking the cylinder to do.
Every Daikin fault code
13 published codes. Filtering happens in the page — every one is in the HTML.
Showing 13 of 13 codes
Daikin models
Codes can differ between generations. Check yours.
Guides that help with Daikin faults
Heat pump defrost and sterilisation cycles: not faults
Vapour off the outdoor unit, ice on the fins, a cylinder heating to 65°C at 3am: the cycles a heat pump runs by design, and what each manufacturer publishes.Read the guideHeat pump faults: what you can check, and who can touch it
Two circuits, two trades. Gauge, isolators and schedule are yours to check; refrigerant is F-Gas work by law. How each code tells you which side it is on.Read the guide
Looking for Daikin’s own support? www.daikin.co.uk. We are not affiliated with Daikin.