Daikin E3 fault codewhat it means and how to fix it

Get it checkedHeat pumpDaikin Altherma heat pumps. Shown as E3 on older displays, E3-00 on the Altherma LT split from at least 2018 and on all Altherma 3 controllers, and E3-24 on the Altherma 3 M, whose table is the only one consulted that carries the second sub-code.Last updated

The outdoor unit’s high pressure switch has opened. Daikin list a closed stop valve, a faulty sensor or switch, overcharge, moisture, a blockage and the fan, and require a manual reset.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get an F-Gas certified heat pump engineer to look at the Daikin properly.

Get an F-Gas certified heat pump engineer to look at your Daikin E3

We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What E3 means

E3 is "OU: Actuation of high pressure switch" in Daikin’s Altherma table, and the service manual describes the trigger precisely: the switch opens because the measured pressure has risen above its operating point. There is a second, quieter route to the same code — if high pressure control, where the pressure sits just below the switch point, occurs sixteen times within three hundred minutes, the unit declares E3 anyway. Either way the unit stops, and the reset is manual, at the user interface. The suffix matters. E3-00 is the switch actuating. E3-24, which appears in the Altherma 3 M table, is listed there as "High pressure sensor abnormality" and headed "High pressure switch abnormality" in the service manual, and its checklist drops the stop valve check and starts with the pressure sensor: a diagnosis pointing at the component rather than the pressure.

Daikin’s checklist for the engineer runs: stop valves on the refrigerant circuit fully open; the refrigerant pressure sensor; the high pressure switch; the main PCB; whether the circuit is overcharged; non-condensables or moisture in the circuit; a clogged circuit; and the outdoor unit fan motor. Notice what that list is about — the refrigerant side and the fan — which is why this is a code for an F-Gas certified engineer rather than a heating engineer.

What an owner can bring is context. If it appeared on a hot day, during the hot water cycle or when the outdoor unit was boxed in by something, say so. And if your controller shows E33, read the code again from the Malfunctioning menu rather than the home screen banner: Daikin’s tables have no E33, and the outdoor unit high pressure code is E3 with a two-digit detail code after it.

What causes it

Causes of the Daikin E3 fault code, most common first
CauseWhat is actually happeningHow likely
Stop valve not fully openDaikin’s first check. A valve left partly closed at commissioning restricts the circuit and pressure climbs on the high side.Common
Pressure sensor or high pressure switch faultyDaikin’s second and third checks. E3-24 on the Altherma 3 M names the component rather than the pressure: sensor in the installer guide, switch in the service manual heading.Common
Overcharge, moisture or a blockage in the circuitThree items on Daikin’s list that all raise head pressure. Every one is inside the sealed refrigerant circuit.Occasional
Outdoor unit fan not moving enough airDaikin’s final check is the fan motor. In cooling mode the outdoor coil is where the heat goes, and a fan that is failing or a coil that is boxed in lets pressure build.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£120–£800

Time on site

15 minutes

A diagnostic visit from an F-Gas certified engineer is typically £120 to £250. A stop valve adjustment or a switch replacement stays near the bottom; recovering and recharging an overcharged or contaminated circuit, or a fan motor, takes it higher.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Daikin E3

My display says E33, not E3. What is E33?

Daikin’s published Altherma tables have no E33. The outdoor unit high pressure code is E3, shown with a two-digit detail code such as E3-00 or E3-24, and a banner that has run the two together is the likeliest explanation. Open the Malfunctioning menu and read the full code there.

Is E3 the same on a Daikin air conditioner?

The headline is similar — Daikin splits also report high pressure under the E family — but this page is written around the Altherma’s outdoor unit and the service manual for it. For a wall-mounted air conditioner, use the Daikin pages in our air-conditioning section.

Why did it happen when nothing seemed wrong?

Possibly because of the sixteen-in-three-hundred-minutes rule. Daikin declare E3 if high pressure control — pressure hovering just under the switch point — happens sixteen times in five hours, even if the switch never actually opens. That is a unit working hard against something, and the engineer’s list will find what.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?