Daikin H4 fault codewhat it means and how to fix it
Malfunction of the low pressure switch, a protection device on the refrigerant side of the outdoor unit. Daikin publish the name and nothing an owner can act on; it is certified work.
Take care
Get an F-Gas certified heat pump engineer to look at your Daikin H4
We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What H4 means
H4 appears in Daikin’s Altherma error table as "Malfunction of low pressure switch", and that is the whole of what Daikin publish for owners. The low pressure switch is a safety device in the refrigerant circuit that opens if the suction pressure falls below a set point, and its purpose is to stop the compressor before it damages itself running on too little refrigerant. So H4 sits next to U0 in practice: one says the charge is short, the other says the device that guards against a short charge has either tripped or failed.
Daikin’s service documentation for the larger Altherma 3 H HT range gives H4-00 a troubleshooting page of its own and lists the low pressure switch among the outdoor unit’s repairable components, which tells you two things — that the switch itself is a replaceable part, and that the diagnosis is a job for whoever can open the outdoor unit. Nobody without F-Gas certification may do that on an R32 or R410A system. It is worth being honest about the limits here. Daikin’s owner-facing table gives a name, not a cause, and we have not read the detailed H4 procedure, so this page will not tell you whether your switch has tripped on genuinely low pressure, failed electrically or lost its connector.
An engineer with gauges will, in about ten minutes. What you can usefully establish is whether the unit still runs at all, whether the code appeared in very cold weather — the extreme of the operating envelope, where suction pressure is at its lowest — and whether anything else showed alongside it, particularly U0. Those three observations shorten the visit.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Refrigerant pressure genuinely low | The switch doing its job: a leak or a short charge has dropped suction pressure below the set point. If U0 has also appeared, this is the likely reading. | Common |
| The switch or its wiring faulty | Daikin’s wording is malfunction of the switch, and their service literature lists it as a replaceable component in the outdoor unit. A failed switch or loose connector reports a problem that is not there. | Common |
| Operating at the cold edge of the envelope | Suction pressure is lowest in the coldest weather. A marginal charge or a restricted circuit that is fine in October can trip the switch in a January cold snap. | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£120–£900
Time on site
10 minutes
A diagnostic visit from an F-Gas certified engineer is typically £120 to £250. A replacement low pressure switch is a modest part on top; a leak repair and recharge is where the range widens.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Daikin fault codes
- U0Get it checkedShortage of refrigerant in the Altherma outdoor unit. Daikin’s own checklist ends with a leak test, the circuit is sealed, and on an R32 unit this is F-Gas certified work by law.Related: refrigerant circuit
- E3Get it checkedThe outdoor unit’s high pressure switch has opened. Daikin list a closed stop valve, a faulty sensor or switch, overcharge, moisture, a blockage and the fan, and require a manual reset.Related: refrigerant circuit
- Bill has jumpedGet it checkedThe most important heat pump fault has no code. If your electricity cost has stepped up with no change in habits, the backup heater is probably doing the work.Related: same brand
- Ice on the outdoor unitGet it checkedNormal in cold damp weather, and the unit clears it itself. Daikin specifically forbid helping — no hot water, no de-icer, no scraping.Related: same brand
- 7HGet it checkedA water flow problem. The sub-code matters more than the code: 7H-01 clears itself, 7H-04 to 7H-06 need a manual reset, 7H-08 is the pump, and 7H-07 is the unit freeing a stuck pump.Related: same brand
- Water at the tap is too coldGet it checkedDaikin give two causes and a remedy that costs money. Before using it, check what your schedule is actually asking the cylinder to do.Related: same brand
Own a Daikin heat pump? Save it and its codes come first next time.
Related guides
Common questions about Daikin H4
What does a low pressure switch actually do?
It is a safety device that opens when the pressure on the suction side of the compressor falls below a set point, stopping the compressor before it runs dry. Daikin name it as a component in their Altherma outdoor units; its purpose is protection, so a trip is the machine looking after itself.
Why will you not tell me the cause?
Because Daikin publish a name for H4, not a cause, and we do not fill that gap from trade lists. The two realistic possibilities — pressure genuinely low, or the switch itself faulty — are stated above with the reasoning behind them, and an engineer with gauges settles it quickly.
Is this an expensive fault?
It depends entirely on which of the two it is. A failed switch is a modest part and a short visit. Genuinely low pressure means a leak to find and repair, which is the more expensive outcome and the reason not to keep resetting the unit in the meantime.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.