Skip to content
FaultcodeCheck

Daikin U4 fault codewhat it means and how to fix it

Get it checkedHeat pumpAltherma ranges. Shown as U4 on older displays and U4-00 on the Altherma LT split from at least 2018 and on all Altherma 3 controllers. On the monobloc 3 M both boards are in the outdoor casing; on the LT split and 3 H F the two units are joined by an interconnection cable that also carries the indoor unit’s power.Last updated

Indoor/outdoor unit communication problem. Daikin’s checks start with the power supply and the wiring between the two boards, and the published reset is a power reset at the outdoor unit.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get an F-Gas certified heat pump engineer to look at the Daikin properly.

Which Daikin appliance is showing U4?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

An Altherma heat pump with radiators or a hot water cylinder

This page is yours. Daikin’s checks start with the power supply and the wiring between the boards, before any board itself.

Check isolators and breakers for both halves, then book your installer.

A wall-mounted air conditioner with a remote control

Daikin publish the same U4 for splits, but the checks belong to that appliance.

Use the Daikin U4 page in the air-conditioning section of this site.

What U4 means

U4 is "Indoor/outdoor unit communication problem" in every Daikin Altherma table: the two halves of the system have stopped talking. It is worth separating from the more serious outdoor unit codes because Daikin’s own checklist starts with mundane things. The service manual for the Altherma 3 M gives the trigger as a communication failure between the outdoor and indoor unit, the effect as the unit stopping, and the reset as a power reset via the outdoor unit — not a button on the controller, and not automatic.

Then the checks, in order: the power supply, which Daikin say must be within 4 per cent of nominal voltage, with a power drop or a short circuit as the named causes; the wiring between the hydro PCB and the main PCB; the main PCB; the outdoor unit fan motor; and the hydro PCB. That list reads differently depending on what you own. On a monobloc such as the 3 M, both boards live in the outdoor unit and the "indoor unit" is the hydro module inside the same casing, so U4 is an internal wiring or board fault plus whatever the mains is doing. On a split — the Altherma LT with an ERLQ outside and a hydrobox inside, or the 3 H F — the two are joined by an interconnection cable that Daikin describe as the indoor unit’s main power supply as well as its communication line, and that cable runs through a wall and along the outside of the house, where rodents, garden work and weathered terminals reach it.

Two published details matter to an owner. Daikin note that if a U4 error occurs, room frost protection is not guaranteed, so an empty house in winter with U4 showing is a pipework risk rather than an inconvenience. And the code is not in the refrigerant circuit, which is where the expensive repairs live; a communications fault is usually wiring, a supply problem or a board. What you can usefully establish before the visit is whether both halves have power, whether anything has tripped at the consumer unit or been left off at an isolator, whether the lights have flickered or the supply has been disturbed, and whether any work has been done outside recently near where the cable runs.

What causes it

Causes of the Daikin U4 fault code, most common first
CauseWhat is actually happeningHow likely
Power supply out of range or disturbedDaikin’s first check. The supply must be within 4 per cent of nominal voltage, and a power drop or a short circuit is enough. Common after a power cut or electrical work nearby.Common
Wiring between the two boards, or the interconnection cable on a splitDaikin’s second check is the wiring between the hydro PCB and the main PCB. On a split system that is the interconnection cable, which runs outside and reaches ground level, where rodents, garden work and weathered terminals find it.Common
Water ingress or corrosion at a terminalOutdoor terminations weather over years. Produces intermittent faults before permanent ones.Occasional
Main PCB, hydro PCB or fan motorDaikin’s third, fourth and fifth checks. The fan motor is on the list because a failed motor can take the board that drives it down with it. Established by an engineer once supply and wiring are proven.Occasional

What to try yourself

  1. Check both halves have power. There is usually a separate isolator for the outdoor unit, and it is easy for one to have been left off. On a split the hydrobox is normally fed from the outdoor unit, so an outdoor isolator left off darkens both.

  2. Check the consumer unit for a tripped breaker or RCD affecting either supply, and think about whether the mains has been disturbed — flickering lights, a power cut, work on the street.

  3. Think about what has happened recently — an electrician working, garden work, fencing, anything digging near where the cable runs outside.

  4. Look at the outdoor unit for obvious damage to the cable where it enters, including chew marks at ground level.

    Look only. Do not open the electrical enclosure on either unit — that is an installer job and the supply is high current.
  5. If the house will be empty in cold weather, do not leave it. Daikin publish that with a U4 error, room frost protection is not guaranteed.

  6. Book your installer and tell them it is U4. Daikin’s published reset is a power reset at the outdoor unit, and their checklist starts with the supply and the wiring, so saying the code shortens the visit.

Get an F-Gas certified heat pump engineer to look at your Daikin U4

We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£90–£600

Time on site

20 minutes

An installer visit is typically £90 to £180 and often resolves it. A damaged interconnecting cable replaced depends entirely on the run. A control board is £300 to £600 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Daikin U4

Is this an expensive fault?

Usually one of the cheaper ones, because Daikin’s own checks put the power supply and the wiring before any board. It is not in the refrigerant circuit, which is where the expensive repairs live.

Can I fix it by turning everything off and on again?

Daikin’s published reset for U4-00 is exactly that — a power reset via the outdoor unit — and Daikin UK’s owner leaflet for the older Altherma LT tells owners they can reset the system by turning the power off, waiting 60 seconds and turning it back on. So once is reasonable. But Daikin’s installer guide says the problem should be understood and dealt with before a code is reset, by a licensed installer or dealer, and repeatedly cycling the power on a system that keeps reporting the same fault is not diagnosis.

I have a Daikin air conditioner showing U4, not an Altherma.

Same code, same headline — Daikin publish U4 as an indoor-to-outdoor transmission failure on their wall splits too — but the units, the wiring and the power-up sequence are the split’s own. This page is written for the Altherma heat pump; the Daikin U4 page in our air-conditioning section is the one for a split.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?