Mitsubishi Electric heat pump fault codes
Ecodan is the one heat pump range whose maker prints a grouping rule: any code beginning U, F or A is an outdoor unit failure, in Mitsubishi’s own words. The rest of the table sorts by first letter closely enough to be read the same way, and that tells you where the fault is and therefore who can touch it.
Where the code shows on a Mitsubishi Electric
The first character is the useful part. Mitsubishi publish one rule themselves: codes beginning U, F or A are "Outdoor unit failure", which is the compressor, the inverter, the pressure switches and the refrigerant, and the group no owner and no ordinary electrician should be opening. The rest is read off their table rather than printed as a rule. L codes are what the indoor FTC controller detects: water overheat and freeze protection, low flow, cylinder overheat, its own thermistors, the pressure and flow sensors, boiler-linked faults and DIP switch settings. P1 and P2 are thermistors and P6 is the plate heat exchanger protection. J codes are the wireless controller link, with J0 and J9 the wired FTC ends of it. E codes are wired communications with the main controller and with the outdoor unit. Mitsubishi call these check codes in their service manuals and error codes on the controller; both are their terms for the same thing. One warning before you look anything up: Mitsubishi’s air conditioners share this two-character vocabulary, and the UK error code lookup returns a separate row per product for many codes. Often the fault is the same, U1 being the same high pressure switch on both, but the published checks are for a different machine, so read the Ecodan row. If your Mitsubishi blows air rather than heating water, use the Mitsubishi Electric pages in our air-conditioning section.
How to reset a Mitsubishi Electric
The controller offers "Reset error? No / Yes" on the error screen. On an FTC5 or FTC6 main controller Mitsubishi’s instruction is "Press the F4 (RESET) button, and the F3 (Yes) button to reset the current error"; on the older FTC4 controller it is to hold button E for three seconds. It is worth understanding what that does before using it. Clearing the message does not clear the condition, and a code that returns after a reset is telling you something. Mitsubishi store up to sixteen previous check codes in an error history with the date each occurred, which means a code you cleared last month is still on record for the engineer — so there is no need to leave a fault showing to prove it happened. If the error screen shows a telephone number, that is your installer’s, entered by them at commissioning.
Most common Mitsubishi Electric faults
The Mitsubishi Electric codes people look up most.
- U1Get it checkedHigh pressure: the outdoor unit’s 63H pressure switch has tripped, at 4.15 MPa on R410A and R32 Ecodans and 3.2 MPa on the R290 range. Mitsubishi say it is usually water flow.
- L9Get it checkedLow flow on the primary circuit. Formally an installer job, but the causes are things you can often see — a dirty filter, a closed valve, air after radiator work.
- No code and nothing happeningGet it checkedMitsubishi resolve four in five support calls on the phone, and publish the four common issues behind them. Three take two minutes and none of them is a code.
- EFGet it checkedA code Mitsubishi define as "non defined": noise on the wiring between the controller, the FTC and the outdoor unit. Their published remedy is to power the Ecodan down for thirty seconds.
Every Mitsubishi Electric fault code
9 published codes. Filtering happens in the page — every one is in the HTML.
Showing 9 of 9 codes
Mitsubishi Electric models
Codes can differ between generations. Check yours.
Guides that help with Mitsubishi Electric faults
Heat pump defrost and sterilisation cycles: not faults
Vapour off the outdoor unit, ice on the fins, a cylinder heating to 65°C at 3am: the cycles a heat pump runs by design, and what each manufacturer publishes.Read the guideHeat pump faults: what you can check, and who can touch it
Two circuits, two trades. Gauge, isolators and schedule are yours to check; refrigerant is F-Gas work by law. How each code tells you which side it is on.Read the guide
Looking for Mitsubishi Electric’s own support? les.mitsubishielectric.co.uk. We are not affiliated with Mitsubishi Electric.