Mitsubishi Electric Outdoor unit failure
Any code starting U, F or A means the outdoor unit; Mitsubishi publish that rule themselves. It is the refrigerant side: F-Gas work on R410A and R32 Ecodans, trained-installer work on the R290 range.
Take care
What this means
This is the one published grouping rule in the whole category, and it is worth more than most individual code meanings. The last row of the FTC self-check table reads, verbatim, "U*, F*, A* — Outdoor unit failure — Refer to outdoor unit service manual". It is printed in the FTC5 and FTC6 installation manuals and again as the last row of Table 4 in the FTC7 cylinder unit service manual; the older FTC4 table has the same row as "U*, F*".
In one line Mitsubishi tell you that any code beginning with those letters points outside the house, at the compressor, the inverter, the fan, the pressure switches and the refrigerant circuit. That matters because it draws the qualification boundary for you, and the boundary depends on what is in the pipes. PUHZ-W and PUHZ-HW outdoor units hold R410A and PUZ-WM and PUZ-HWM hold R32; both are fluorinated gases, and work on a circuit containing them requires F-Gas certification in the UK, a statutory requirement rather than a manufacturer preference.
The PUZ-WZ Ecodan R290 range holds R290, a hydrocarbon that is not an F-gas; there the law does not demand the certificate, but Mitsubishi describe R290 as a highly flammable refrigerant and the outdoor unit is for trained installers, not a general handyman. Either way, a U, F or A code is not something to hand to somebody without the right qualification for your unit. It is also the group where the machine is most likely to have protected itself rather than broken: the high pressure switch and the inverter protections trip for reasons that include a blocked air path, a water flow problem indoors and unusually hot or cold weather, and an engineer may find nothing failed at all. What you can usefully do before the visit is rule out the outside causes: snow, leaves, garden waste, a fence panel or a wheelie bin blocking the airflow, all of which make an outdoor unit work far harder than it should.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Restricted airflow around the outdoor unit | Leaves, snow, garden waste or something stacked against it. The one cause you can see and clear yourself. | Common |
| Pressure switch tripped protectively | Often a consequence of restricted airflow or extreme weather rather than a failed component. | Common |
| Inverter or compressor fault | The serious end of this group. Diagnosed from the outdoor unit’s own board, which is engineer territory on every Ecodan range. | Occasional |
| Refrigerant charge lost through a leak | On an R410A or R32 Ecodan only an F-Gas certified engineer may investigate, recover or recharge; that is law, not competence. On the R290 range it is a flammable hydrocarbon and a trained installer’s job. | Occasional |
What to try yourself
Go and look at the outdoor unit. Clear snow, leaves and garden debris away from the grille and from the space around it.
Check nothing has been put against it — a bin, a fence panel, a stack of pots, a garden chair. It needs a clear path for a lot of air.
Do not pick ice off the fins or pour anything on the unit, even if it is iced up.
The fins are thin aluminium with refrigerant pipework directly behind them. Puncturing that releases a mildly flammable gas on an R32 unit and a highly flammable one on the R290 range, and turns a service call into an incident.Note the exact code and whether the system is still producing any heat. Both are useful and neither costs anything.
Read the refrigerant off the outdoor unit’s nameplate, then book accordingly. R410A or R32: ask specifically whether the engineer holds F-Gas certification, because for those gases it is a legal requirement. R290: ask for an installer trained on the Ecodan R290 range.
Get an F-Gas certified heat pump engineer to look at your Mitsubishi Electric heat pump
We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What it costs to fix
Typical repair cost
£120–£1,200
Time on site
20 minutes
A diagnostic visit from an F-Gas certified engineer is typically £120 to £250. Beyond that the range is very wide — a pressure switch or a fan motor is a few hundred pounds, a compressor replacement can run past £1,000 and is often the point at which the age of the unit decides it.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Mitsubishi Electric fault codes
- U1Get it checkedHigh pressure: the outdoor unit’s 63H pressure switch has tripped, at 4.15 MPa on R410A and R32 Ecodans and 3.2 MPa on the R290 range. Mitsubishi say it is usually water flow.Related: refrigerant circuit
- L9Get it checkedLow flow on the primary circuit. Formally an installer job, but the causes are things you can often see — a dirty filter, a closed valve, air after radiator work.Related: same brand
- No code and nothing happeningGet it checkedMitsubishi resolve four in five support calls on the phone, and publish the four common issues behind them. Three take two minutes and none of them is a code.Related: same brand
- EFGet it checkedA code Mitsubishi define as "non defined": noise on the wiring between the controller, the FTC and the outdoor unit. Their published remedy is to power the Ecodan down for thirty seconds.Related: same brand
- L3Get it checkedCirculation water temperature overheat protection. The flow rate has probably dropped, and Mitsubishi list three things to check: a water leak, a blocked strainer and the pump.Related: same brand
- J1Get it checkedThe wireless receiver cannot hear the wireless room controller. Mitsubishi’s first check is the controller’s batteries, and J1 to J8 all mean the same thing.Related: same brand
Own a Mitsubishi Electric heat pump? Save it and its codes come first next time.
Related guides
Common questions
Can my regular heating engineer look at this?
On an R410A or R32 Ecodan, only if they hold F-Gas certification. Handling fluorinated refrigerant is legally restricted in the UK, so a competent heating engineer without that certificate can check the water side and the electrics but may not open the refrigerant circuit. Mitsubishi’s own training material draws the same line: a heating engineer can install and service a monobloc, but maintaining F-gas parts is for an F-Gas engineer. On the R290 range the certificate is not the legal test, but the refrigerant is highly flammable and Mitsubishi restrict the unit to trained installers.
Which refrigerant does my Ecodan have?
It is on the nameplate on the outdoor unit, and the model number tells you too: PUHZ-W and PUHZ-HW are R410A, PUZ-WM and PUZ-HWM are R32, and PUZ-WZ is the Ecodan R290 range. The first two are F-gases; R290 is not.
How do I know if my code is in this group?
By its first letter. Mitsubishi print the rule in the FTC installation manuals and service manual: codes starting U, F or A are outdoor unit failures. Codes starting L, P, J or E are indoor or controller faults.
The system is still heating. Is it urgent?
Less urgent, but do not leave it. Check whether the backup immersion heater has taken over, because that keeps the house warm at roughly the cost of direct electric heating and the first sign is usually the bill rather than the temperature.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.