Vaillant F.1120 fault codewhat it means and how to fix it
Phase failure on the electric back-up heater: its internal circuit breaker has opened. Vaillant say the competent person resets it, and warn the anti-legionella function is not guaranteed meanwhile.
Take care
Get an F-Gas certified heat pump engineer to look at your Vaillant F.1120
We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What F.1120 means
F.1120 is the one heater fault Vaillant explain to owners directly rather than only in the installer appendix. The indoor unit, they write, has an internal circuit breaker which switches off the heat pump in the event of short circuits or the failure of one current-carrying phase on a 230 V unit, or several on a 400 V unit. When the breaker has opened on the electric back-up heater, the display shows F.1120, and Vaillant’s instruction to the owner is to inform the competent person so that they can eliminate the fault and reset the internal circuit breaker.
They add a consequence worth taking seriously: if the electric back-up heater is defective, the anti-legionella function is not always guaranteed, because heat pump systems rely on that heater to take the cylinder above 60 °C. The installer appendix gives the causes as a defective back-up heater, poorly tightened electrical connections and mains voltage that is too low, with remedies of checking the heater and its power supply, checking the connections, and measuring the voltage at the heater’s connection.
Vaillant UK’s owner page widens the supply-side list — incoming mains outside tolerance, incorrect phases, reverse polarity, poor earthing, an unstable supply — and says this is a case for the installer in the first instance because it can relate to the power supply, with Vaillant engineers for the heater itself. Two everyday versions are worth knowing. On many installations the back-up heater has its own supply and its own breaker in the consumer unit, and that breaker being off produces a phase failure with nothing defective at all. And a loose connection at a heater terminal heats up under the heater’s current, which is why Vaillant list tightness of connections before the heater itself.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Supply to the back-up heater interrupted | A breaker off or tripped in the consumer unit, or an isolator switched off during other work. Vaillant name low mains voltage; no mains voltage looks the same to the heater. | Common |
| Poorly tightened electrical connections | Vaillant’s second cause. A terminal carrying the heater’s current heats and loosens further, and the phase drops out under load. | Common |
| Electric back-up heater defective | Vaillant’s first-listed cause and the expensive one: a failed element or its contactor. | Occasional |
| Mains supply outside tolerance | From Vaillant UK’s list — incorrect phases, reverse polarity, poor earthing, an unstable supply. A three-phase installation with one phase down is the classic. | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£90–£450
Time on site
15 minutes
Nothing if a breaker was off. An installer or electrician visit is typically £90 to £180; a replacement back-up heater element or contactor runs to £250 to £450 fitted.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Vaillant fault codes
- Sterilisation cycleUsually simple to fixVaillant call it the anti-legionella function: the cylinder is driven above 60 °C on set days, usually at 4 a.m., by the electric back-up heater. It looks like a fault and is not one.Related: hot water and cylinder
- F.1100Get it checkedThe safety cut-out on the electric back-up heater has opened. Vaillant name low flow, air, a heater run on an unfilled circuit, a trip above 89 °C that needs a new fuse, and external heat.Related: hot water and cylinder
- F.821Get it checkedSensor fault on the immersion heater flow temperature. Vaillant give a disconnected or short-circuited sensor, or both flow sensors failed, and the fix is a sensor or a cable harness inside the indoor unit.Related: hot water and cylinder
- F.22Get it checkedWater pressure too low. Vaillant publish exact thresholds and two instructions: the indoor unit manual says inform your competent person; Vaillant UK’s fault page lets a competent owner top up to 1 to 1.5 bar.Related: same brand
- Vapour from the outdoor unitUsually simple to fixA cloud rising off the outdoor unit is the defrost cycle. Vaillant’s own wording is that you do not have to do anything.Related: same brand
- Running all the timeUsually simple to fixA heat pump is meant to run long and low. The alarm signal is not the running time, it is the bill — and turning the thermostat up will not warm the house faster.Related: same brand
Own a Vaillant heat pump? Save it and its codes come first next time.
Related guides
Common questions about Vaillant F.1120
The house is warm. Do I need to do anything?
Yes, but not urgently. The heat pump is running without its back-up, which is fine in mild weather. Vaillant’s warning is that the anti-legionella function is not guaranteed while the heater is out of action, and the coldest days will be short of their top-up. Book it rather than leave it.
Can I reset the internal breaker myself?
Vaillant’s wording is that you inform the competent person so that they can eliminate the fault and reset the internal circuit breaker. The breaker is inside the indoor unit behind the electrical cover, and resetting it without finding the cause simply reproduces the fault under load.
Why is this an installer job rather than Vaillant’s?
Because Vaillant UK’s cause list is mostly about the supply: mains voltage out of tolerance, wrong phases, reverse polarity, poor earthing, an unstable supply, and the wiring to the heater. Those belong to whoever installed the electrics. Only a defective heater is a Vaillant part.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.