Get it checkedRange cooker2022-generation documentation only — the Stoves Richmond, Precision and Sterling Deluxe electric induction 100–110cm manual, part 084006000. Not published in the 2025-generation guides.Last updated

E8 is a 2022-generation Stoves code for a fan blocked or faulty. Their published remedy is to check the fan inlet at the rear of the appliance.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a qualified appliance engineer to look at the Stoves properly.

What is the fan actually doing?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

What is the fan actually doing?

This is the case Stoves’ remedy is written for. Clearing the inlet is the published action and no parts are implied.

Clear and clean the inlet at the rear, then retest.

What is the fan actually doing?

Not this code, and not a fault. Stoves publish run-on of around an hour as normal, designed behaviour on a well-insulated oven.

Leave it to finish, and ask customer care about the free modification that reduces run time to around 30 minutes if it bothers you.

What is the fan actually doing?

Consistent with the faulty fans half of Stoves’ published cause. No further owner remedy is published.

Contact Stoves customer care on 0344 815 3740.

What E8 means

E8 comes from the same 2022 Stoves troubleshooting table as E6 and it is worth reading carefully, because the fan is the single thing on a Stoves range cooker that owners most often mistake for a fault when it is working normally. Stoves state the problem as fan blocked or faulty, the possible cause as fan inlets are blocked or faulty fans, and the solution as check fan inlet at the rear of the appliance.

Note the shape of that remedy: it is the only code on the older Stoves table besides ER03 where the published solution is something an owner can actually go and look at. The fan inlet is at the rear, which on a freestanding 100cm or 110cm range cooker means pulling the appliance forward, and what blocks it is usually mundane — the cooker pushed hard back against the wall, packaging or a cloth that has found its way behind, or a build-up of dust and grease on the inlet grille. This is not the same thing as the cooling fan running on after you have finished cooking, and confusing the two sends people looking for a fault that does not exist. Stoves publish the run-on separately and explicitly as normal: the ovens are very well insulated, the cooling fan runs for longer than on previous models to bring the appliance down to a low temperature, it may run for around an hour after cooking has finished, and it does not use much electricity. They also publish an instruction that matters here — do not switch the cooker off at the wall before the cooling fan has stopped completely. A fan that runs for an hour after dinner is behaving as designed. A fan that is blocked, or one that has stopped when it should be running, is what E8 is about.

If the run-on is what bothers you rather than a code, Stoves publish something unusually generous that is worth knowing: they offer an optional free modification to relevant models which starts the fan immediately when the grill is turned on and stops it sooner, reducing the run time to around 30 minutes, and the way to ask about it is to call customer care. As with E6, E8 does not appear in the 2025-generation Stoves guides at all, so if this code is in your manual you are reading the older table.

What causes it

Causes of the Stoves E8 fault code, most common first
CauseWhat is actually happeningHow likely
Blocked fan inletsThe first cause Stoves list. The inlet is at the rear of the appliance, which is exactly where a cooker pushed back against the wall or a build-up of dust will restrict it.Common
A faulty fanThe second half of Stoves’ stated cause, faulty fans. Distinct from a blockage because clearing the inlet changes nothing, and it is not something they publish an owner remedy for.Occasional
Grease and dust loading the inlet grilleThe slow version of a blockage. Nothing is visibly in the way, but the inlet has been progressively closing up over months of cooking rather than being obstructed on one particular day.Occasional

What to try yourself

  1. Let the cooker cool and let the cooling fan finish running before you touch anything. Stoves publish that the fan may run for around an hour after cooking and that you should not switch the cooker off at the wall before it has stopped completely.

  2. Switch the cooker off at the wall once the fan has stopped, so the appliance is isolated while you work behind it.

    A 100cm or 110cm range cooker is heavy and is normally hardwired. Get help to move it and do not drag it by the door handles.
  3. Check the fan inlet at the rear of the appliance. That is Stoves’ published solution for this code, word for word.

  4. Clear anything obstructing it — packaging, cloths, or the cooker itself sitting hard against the wall — and clean dust and grease off the inlet grille.

  5. Restore power and use the cooker normally, then check the fan runs on after cooking as Stoves describe.

  6. If the code returns with a clear inlet, that points at the faulty fans half of Stoves’ cause. Contact customer care on 0344 815 3740.

Get a qualified appliance engineer to look at your Stoves E8

We do not pass enquiries to a repair firm, so there is no form here. When you book a qualified appliance engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£0

Time on site

30 minutes

Clearing the inlet costs nothing. Stoves do not publish a price for fan replacement if the inlet is clear and the code persists.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Stoves E8

Is my Stoves cooling fan faulty if it runs for an hour after cooking?

No, and Stoves publish that plainly. The ovens are very well insulated, the fan runs longer than on previous models to bring the appliance down to a low temperature, around an hour is normal, and it uses very little electricity. E8 is a different thing — a blocked or faulty fan, not a fan doing its job.

Can Stoves make the fan stop sooner?

They publish an optional free modification on relevant models. It starts the cooling fan immediately when the grill is turned on and stops it sooner after cooking, reducing the run time to around 30 minutes, and they ask you to contact customer care on 0344 815 3740 for more information.

Where is the fan inlet on a Stoves range cooker?

Stoves place it at the rear of the appliance, and their published solution for E8 is to check the fan inlet at the rear. On a freestanding 100cm or 110cm cooker that means moving the appliance forward, which is a two-person job.

Why does my current Stoves guide not list E8?

Because E8 belongs to the 2022 generation of Stoves documentation. The current guides list only ER03 and E2 as codes. E8 and E6 were both dropped and Stoves do not publish what replaced them, so a manual containing E8 tells you which table you are reading.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?