Vaillant boiler with no hot water
Read the display before anything else. Vaillant separate status messages from faults, and an ecoTEC that appears to have stopped is often telling you it is deliberately waiting.
What it usually means
Vaillant give you more information than most manufacturers, and using it properly is the fastest route through this fault. An ecoTEC display shows two kinds of message. Codes beginning with F are faults and the boiler has stopped. Codes beginning with S are statuses, describing what the appliance is doing at that moment during entirely normal operation. Confusing the two sends people to the phone when the boiler is working as designed.
One status in particular explains a common version of this complaint. There is a deliberate waiting period after the boiler has been running, during which it will not fire again immediately, and Vaillant publish it as a status rather than a fault. If your hot water goes cold partway through, or the boiler refuses to relight straight after the heating has been on, look at the display before assuming a component has failed — an appliance in a documented pause is not a broken one.
The next Vaillant particular is how the boiler knows you have opened a tap. On these appliances hot water demand is sensed by water actually moving through the boiler, and if that sensing element sticks — which it does, with scale or debris, and more often on older units — the boiler never learns that anybody wants hot water. Everything else works, the heating is faultless, and no amount of turning taps produces a response. It is one of the more satisfying faults to find because the symptom is so absolute and the part is small.
Then there is the code that has been misdiagnosed more than any other on this platform. Vaillant's pressure-and-pump fault appears when the boiler cannot see the pressure change it expects when the pump starts, and it stops the appliance doing anything, hot water included. It gets blamed on the pump, on the sensor and on the board in roughly equal measure, and the honest position is that it needs someone who knows the platform rather than someone replacing parts in order. If that is the code on your display, say so when you book.
Vaillant also have their own preheat arrangement, which changes how quickly water arrives without changing whether it arrives at all. With it enabled the boiler holds itself ready and hot water is quick; with it off you wait longer at the tap. A household that has recently had a service, a new control fitted or a power cut may find the setting has moved, and the resulting delay reads exactly like a fault.
After all of that, the ordinary mechanics apply as they do to any combi: a diverter valve stuck towards the heating circuit gives hot water only while the heating runs, a scaled plate heat exchanger gives a gradual decline over years rather than a sudden stop, and low system pressure stops everything. And if your Vaillant feeds a cylinder rather than being a combi, the hot water is made outside the appliance, so the cylinder thermostat and the motorised valve come first.
How to narrow it down
Work through these in order.
Does the display show an F code or an S code?
This is the first and most Vaillant-specific question. F means a fault and the boiler has stopped; S means a status and the boiler is describing normal behaviour. Getting this right saves a call-out, because several of the S codes look alarming and mean the appliance is in a deliberate, documented waiting period.
Does it go cold partway through, or refuse to relight straight after heating?
Both are consistent with the built-in waiting period rather than a failure. Watch the display while it happens and note what it shows. If it is a status code, the answer is patience or a control adjustment; if it is a fault code, you have something concrete to look up and to quote.
Does the boiler react at all when you open a hot tap?
Stand next to it and listen with a tap running. A boiler that stays completely silent is not detecting demand, and on these appliances demand is sensed by water moving through the boiler — a sensing element that has stuck with scale or debris produces exactly this: perfect heating, no response to any tap.
Does the heating work normally?
Run it for ten minutes even in summer. Heating working narrows the fault to the hot water side: the demand sensing, the diverter valve, the plate heat exchanger. Neither working sends you to system pressure first, and on an ecoTEC there are specific codes for both low pressure and for the pump not producing the change the boiler expects.
What is the system pressure reading cold?
Look at the gauge with the heating off and cold. Below about 0.5 bar the boiler stops entirely, hot water included, and Vaillant publish precise thresholds for it. If it is low, top it up to 1.2 and note whether it stays there, because a system that needs filling every few weeks has a leak rather than a maintenance need.
Has the preheat or comfort setting changed?
Vaillant let you keep the boiler ready for instant hot water or let it fire only on demand, and the second is slower at the tap. Settings move after a service, a new control or a power interruption, so if the water arrives eventually but takes far longer than it used to, this is worth checking before anything else.
Do you get hot water only when the heating is running?
That points squarely at the valve that directs heat between the two circuits having stuck towards heating. It is a known failure on combis, the symptom is unmistakable, and describing it in those words when you book gets you an engineer carrying the right part rather than one diagnosing from scratch.
Is there a hot water cylinder in the house?
If there is, your Vaillant is a system or heat-only boiler and the hot water is made in the cylinder. That moves the investigation outside the appliance: the cylinder thermostat, the motorised valve on the pipework, and whether the programmer is calling for hot water at the time you are testing it.
Codes commonly shown with this
- F.22VaillantThe boiler has shut down because there is not enough water in the system. Pressure has dropped below roughly 0.5 bar and it will not fire until you top it up.Get it checked
- F.75VaillantThe boiler cannot detect a rise in pressure when the pump starts, so it has locked out. Usually a failed pressure sensor or a pump that is not moving water.Get it checked
- F.28VaillantThe boiler tried to light and failed every attempt it is allowed — three on an ecoTEC, five on the 2022 CS/1-5 — so it has shut the gas off and locked out.Stop — call an engineer
- F.24VaillantTemperature is rising faster than it should when the burner fires. That is a circulation problem caught a step earlier than an overheat.Get it checked
- S.53VaillantNot a fault. Your boiler is in a deliberate waiting period because the gap between flow and return temperatures is too wide, which points at poor circulation.Get it checked
- F.83VaillantThe burner lit but neither sensor saw the temperature rise it should have. Either water is not moving through the boiler, or a sensor is misplaced.Get it checked
When it is urgent
Take care
What it costs
Typical repair cost
£120–£450
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Get an engineer to look at this
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.