Air conditioner Outdoor unit not runningwhat to check

Get it checkedAir conditionerLast updated

Usually not dead at all. A restart delay, a defrost or a satisfied room stops the outdoor unit by design, and on a domestic split a lit indoor unit means the supply is on.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get an F-Gas certified heat pump engineer to look at the air conditioner properly.

What this means

An indoor unit that blows air while the outdoor unit sits silent is a specific and quite readable symptom, because the outdoor unit is where the cooling actually happens. The indoor fan will run happily on its own and move room-temperature air around, which is why this presents as an air conditioner that is on but useless rather than one that is dead. Start with the idea most people bring to it, because it is wrong for this equipment. A domestic split has one mains supply feeding both units. Daikin’s installer guide for their outdoor units warns not to connect the power supply to the indoor unit at all; Mitsubishi’s service manual for the MSZ wall units has the main supply landing on the outdoor unit’s terminals, with the indoor unit fed over the three-core connecting wire; Toshiba wire the power cord to the outdoor unit as standard, with a supply into the indoor unit as the option. Whichever end it arrives at, the other end is fed from it.

So if the indoor unit is lit and taking commands, the outdoor unit has power, and an isolator or breaker that had been switched off would have taken both units down together. That does not make the isolator irrelevant — a system that is completely dead, with no lights and no response to the remote, is exactly the case for the isolator and the consumer unit, and it is the first thing on Daikin’s and Toshiba’s owner checklists for a unit that does not operate. It just means that a live indoor unit and a silent outdoor unit is not a power problem, and the explanations are elsewhere. Most of them are not faults at all. Compressors do not restart instantly: Toshiba publish a three-minute protection feature that stops the unit being activated for three minutes after a sudden restart, and Daikin say the system resumes about three minutes after a power failure or after stopping itself on a large voltage fluctuation, so a unit switched off and straight back on sits doing nothing for several minutes by design.

In heating, a reversible unit periodically melts frost off the outdoor coil: Daikin say hot air stops coming from the indoor unit during defrosting and that the frost melts into water or steam at the outdoor unit, and Toshiba say the fans stop during defrost operation. And a system that has satisfied the room temperature has nothing to do, so the outdoor unit stops while the indoor fan carries on — Toshiba describe exactly that, with the fan speed reduced and the outdoor unit stopping once the set temperature is reached. None of those are faults. Beyond that, the published faults in this area are mostly communication and power. Manufacturers publish codes for transmission failure between the indoor and outdoor units, and the causes are wiring, the power-up sequence and the supply rather than the machinery. Mitsubishi make a specific point that is easy to miss: they name the system having been powered up incorrectly as a cause, and their remedy is to repower in the correct sequence, indoor unit first and then outdoor. That is an installer action, but it explains why a fault sometimes appears immediately after unrelated electrical work.

What causes it

Causes of Outdoor unit not running, most common first
CauseWhat is actually happeningHow likely
A normal protective delay after stoppingCompressors do not restart immediately. Toshiba publish a three-minute protection after a restart and Daikin a resumption about three minutes after a power failure, so a unit switched off and straight back on sits apparently dead for several minutes, by design.Common
The room has reached temperatureThe outdoor unit stops when there is nothing to do while the indoor fan carries on. Toshiba describe it under warm air control: fan speed reduced and the outdoor unit stopping once the set temperature is reached.Common
A defrost cycle in heating modeThe system periodically melts frost off the outdoor coil. The fan may stop, the unit may steam, and to anyone watching it looks like a breakdown.Common
The whole system is off at the isolator or breakerThe genuine power case, and it looks different: nothing lights, nothing answers the remote. One supply feeds both units, so a switched-off isolator or a tripped breaker takes the indoor unit down too. A device that trips repeatedly is reporting something and should not simply be reset again.Occasional
A communication fault between the unitsPublished by every manufacturer here. Causes are wiring, the power-up sequence and the supply rather than the compressor — Mitsubishi name incorrect power-up specifically.Occasional

What to try yourself

  1. Look at the indoor unit first. If it is lit and answers the remote, the supply is on and the outdoor unit has power — skip the isolator and go to the next steps. If nothing at all is lit, check the isolator near the outdoor unit and the consumer unit, which is Daikin’s and Toshiba’s first owner check for a unit that does not operate.

    If a breaker has tripped, reset it once. If it trips again, leave it off and get it looked at — a protective device operating repeatedly is detecting something rather than being temperamental.
  2. Wait at least three minutes before concluding anything, and preferably ten. Toshiba and Daikin both publish a delay of about three minutes before the unit runs again after a restart or a power cut, and that delay is deliberate.

  3. Check the setpoint against the room. A system that has reached temperature stops the outdoor unit and keeps the indoor fan turning, which is the commonest reason of all for a quiet outdoor unit.

  4. If you are running in heating and the unit is steaming with the fan stopped, leave it alone. That is a defrost cycle and it ends by itself.

  5. Look around the outdoor unit. Nothing should be blocking its air inlet or outlet — planting, a cover, fencing or packed leaves — because a unit that cannot reject heat will trip its protections and stop. Clear it without removing any panels.

  6. If there is power, no delay, and no defrost, retrieve the fault code and pass it on. Communication faults and compressor faults look identical from the garden and are very different jobs.

Get an F-Gas certified heat pump engineer to look at your air conditioner

We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£0–£350

Time on site

30 minutes

Nothing if it was a delay, a defrost, a satisfied room or a switched-off supply, which covers a good share of these. An engineer visit for a communication fault, and considerably more if it is the fan motor or compressor.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions

Where is the isolator, and is it the problem?

Usually a small weatherproof switch mounted on the wall within sight of the outdoor unit, though it is sometimes just inside the building where the cable enters. It exists so an engineer can make the unit safe without going to the consumer unit. It is only the problem if the whole system is dead: on a domestic split one supply feeds both units, so if the indoor unit is lit and responding, the isolator is on and the outdoor unit has power. A silent outdoor unit under a live indoor unit is a delay, a defrost, a satisfied room or a fault — not the switch.

The outdoor unit is steaming. Is it on fire?

No, that is water vapour and it means the system is in a defrost cycle, which only happens when it is running in heating. The unit briefly warms the outdoor coil to melt the frost off it, and the steam is that frost evaporating. It stops on its own.

It hums but the fan does not turn.

That needs an engineer rather than more attempts. It can be a fan motor, a capacitor, or a compressor trying to start against a fault, and repeatedly switching it on and off while it is in that state is not doing it any good. Retrieve the code if you can and stop using the system.

Can I clean the outdoor unit myself?

You can clear leaves and debris from around it and brush loose material off the outside of the fins, and keeping the airflow clear genuinely helps. What you should not do is remove panels, wash it out with a hose, or straighten fins with anything metal — there is mains voltage inside and refrigerant pipework you can damage easily.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this