Air conditioner Water dripping from the indoor unitwhat to check

Get it checkedAir conditionerLast updated

Usually a blocked drain rather than a failed pump. Mitsubishi say so directly: their pump runs constantly in cooling and rarely fails.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get an F-Gas certified heat pump engineer to look at the air conditioner properly.

What this means

This is the most reported air conditioning problem in a British home and it has a published answer that will save you money. Cooling air makes water. The indoor unit is pulling moisture out of the room by design, that water collects in a tray underneath the coil, and it has to get outside. When it appears on your wall or your floor instead, something in that path has stopped working. The instinct, and the thing you will often be told, is that the condensate pump has failed. Mitsubishi address that head on, and their wording is worth having in front of you before anybody quotes for a part: do not assume the drain pump is faulty here, because on their equipment the drain pump runs whenever the unit is in cooling mode, it is a very reliable and robust piece of equipment and does not often fail. The most common cause is a drain pipe or drip tray blockage causing the water to back up, so inspect the drip tray, the drain pipe and the float switch or sensor before ordering parts. That is a manufacturer telling engineers not to sell you a pump.

Before that, though, a question that decides which half of this page applies to you: does your unit have a pump at all? Most wall-mounted domestic splits do not. Daikin’s, Mitsubishi’s and Toshiba’s wall units drain by gravity through a hose that runs out with the pipework — their installation manuals route a drain hose and nothing else — and Mitsubishi’s MSZ wall units have no drain fault in their code table because there is no float switch to raise one. On those the whole question is the hose: blocked at the outside end, kinked, crushed behind the unit, or running uphill somewhere. Pumps and float switches belong to ceiling cassettes, ducted units and wall units where an installer has added a pump to lift the water. Note what has actually happened when a pump-equipped system reports this rather than just leaking.

Mitsubishi publish codes for a drain fault and for a high condensate level in the drip tray, and both are triggered by a float switch detecting water backing up. So the machine is not failing to pump; it is detecting that the water is not going anywhere and stopping to avoid flooding your room. That is protection working. What you can reasonably do yourself is limited to the outside end. The condensate pipe usually exits through the wall behind or below the indoor unit and drips onto a patio or into a drain, and that outlet gets blocked by leaves, algae, insects and nests. Finding it clear or blocked is genuinely useful information, and Daikin give you a test: check that water comes smoothly out of the drain hose while the unit runs in cooling or dry mode, because if none appears, water may be leaking from the indoor unit and their instruction is to stop and consult the service shop. Everything above the outlet — the tray, the float, the pump — is inside a unit with mains voltage in it and belongs to an engineer, and the manufacturers say the same about the leak itself: Daikin list water leaking from the indoor unit among the symptoms for which you turn the breaker off and call the service shop immediately, and Mitsubishi list water leaking or dripping from the indoor unit among the cases in which to stop using the air conditioner and consult the dealer.

What causes it

Causes of Water dripping from the indoor unit, most common first
CauseWhat is actually happeningHow likely
A blocked condensate drain pipeMitsubishi’s named most common cause. The water backs up because it has nowhere to go, and the tray overflows or the float switch trips.Common
A blocked or dirty drip trayAlso named by Mitsubishi. Dust from the room combines with condensation into a sludge that blocks the tray outlet before it blocks the pipe.Common
The outside end of the pipe obstructedThe bit you can actually see. Leaves, algae, insect nests and pointing debris all block a condensate outlet, and it is the one part of the path an owner can inspect.Common
A dirty indoor filter causing the coil to iceIce on the coil melts all at once when the unit stops, which overwhelms the tray. The symptom is water, but the cause is airflow.Common
A float switch or drain sensor faultThe genuine electrical case. Mitsubishi publish a separate drain sensor code and note that an open or short circuit on the sensor produces it with a perfectly clear tray.Occasional

What to try yourself

  1. Stop the system and turn it off at the breaker or isolator, which is what Daikin and Mitsubishi both tell owners to do when water is leaking from the indoor unit, so nothing is adding water while you look and nothing is live near it.

  2. Find where the condensate pipe comes out of the wall outside — usually behind or just below the indoor unit — and check the end is clear.

  3. Look at whether that pipe runs downhill all the way. A section that has sagged or been knocked upwards holds water and stops the rest draining. Toshiba’s installation instruction is that the hose slopes continuously and is never allowed to go slack, and Daikin’s owner test is that water should come smoothly out of it while the unit cools.

  4. Take the indoor filter out and look at it. A blocked filter ices the coil, and the meltwater arrives faster than the tray can handle it.

  5. Note whether the unit has reported a code and retrieve it if you can. A drain fault and a drain sensor fault look identical from the floor and lead to different repairs.

  6. Call an engineer for anything inside the indoor unit, and mention what you found outside.

    Do not open the indoor unit beyond the filter cover. The tray sits directly under the coil alongside the fan motor and mains wiring, and water and electricity are already in contact in there.

Get an F-Gas certified heat pump engineer to look at your air conditioner

We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£80–£250

Time on site

45 minutes

A drain clear and service is the usual outcome and sits at the lower end. A float switch or drain sensor replacement costs more, and a genuine pump failure — which the manufacturer says is uncommon — more again.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions

Do I need a new pump?

Probably not, and Mitsubishi say as much. Their own guidance to engineers is not to assume the pump is faulty, because it runs whenever the unit is cooling, it is robust and it does not often fail — the usual cause is a blockage backing the water up. Ask for the tray and the pipe to be checked before you agree to a pump. And check first whether you have one: an ordinary wall-mounted split drains by gravity and has no pump to fail.

Why has it only started now?

Condensate blockages build up gradually and then fail suddenly. A tray silts up over years and only overflows once the remaining channel closes. Weather matters too — a humid spell makes far more water than a dry one, so a marginal drain that coped in June fails in August.

It leaks only when it is really hot.

That fits a partially blocked drain rather than a completely blocked one. On a hot humid day the unit produces more condensate than the restricted path can carry, so it backs up; on a milder day the same restriction keeps up. It still needs clearing.

Can I just put a bowl under it?

Only as a stopgap while you arrange a repair. Water is running somewhere it was not designed to, close to the fan motor and the electrical side of the indoor unit, and the longer that continues the more likely it is to cause a second and more expensive problem.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this