Toshiba 01 - 04 fault codewhat it means and how to fix it
Indoor to outdoor communication on the RAS range. Toshiba’s own list starts with the connecting cable and includes the outdoor unit’s protectors — and read the code before you switch anything off.
Take care
What 01 - 04 means
Toshiba publish detail code 04 under initial code 01 as an indoor to outdoor communication fault, noting that it includes the compressor thermostat, and they publish 05 in the same group as another indoor to outdoor communication row. On the initial code 03 group, 07 covers the same ground again. So communication between the two halves of the system is described in more than one place in Toshiba's table, which is worth knowing when you are trying to match what your unit is showing. The two halves of a split talk continuously over the connecting cable that runs with the refrigerant pipes, and on a Toshiba domestic split that cable also carries the power for whichever unit the mains does not reach: as standard the power cord goes to the outdoor unit and the indoor unit is fed from it over the three numbered cores, with a supply into the indoor unit offered as the alternative.
One supply, both units. So a communication fault here does not mean the outdoor unit has quietly lost power while the indoor unit carries on — if the supply were off, nothing would light up at all. What Toshiba's current service manual actually lists for the serial signal fault is, in order: defective wiring or mis-wiring of the connecting cable; the operation signal not being sent by the indoor unit; the outdoor unit not returning its signal when operation starts, for which the engineer checks the fuses on the inverter board; and the return signal stopping during operation, which the manual attributes to a protector in the outdoor unit opening — the high-pressure switch or a thermal relay — with the instruction to check the refrigerant amount or anything else that could cause high temperature or high pressure. That last cause is the one to hold on to, because it means a Toshiba communication code can be the outdoor unit protecting itself rather than a wiring fault, and it is why the manual says to check any other codes found at the same time.
The timing is also published: the indoor unit sends for a minute, waits three, sends again, and flashes the error a minute after that, so the code appears roughly five minutes after the outdoor unit stops answering. The thing that makes this code particular to Toshiba is the order of operations. Their technical handbook says not to turn the power off before reading the fault codes, because that clears the diagnostic memory; their current service manual says the codes survive a power cycle. You cannot tell which you have from the room, and on a communication fault the temptation to cycle the power is at its strongest, so read the code, write down both parts, and then try the power. If it clears and never returns, that was a transient. If it comes back, you now have the evidence. What remains after that is the connecting cable, which runs outside and is exposed to weather, rodents and anyone working on that wall, the fuses and protectors in the outdoor unit, and the control boards at either end.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| A fault in the connecting cable | First on Toshiba’s list: defective wiring or mis-wiring of the connecting cable. It runs outside with the pipework and is exposed to weather, rodents and building work, and it carries the fed unit’s power as well as the signal. | Common |
| The outdoor unit protecting itself | Toshiba’s fourth cause: the return signal stops because a protector in the outdoor unit — the high-pressure switch or a thermal relay — has opened, and they say to check the refrigerant amount and anything else causing high temperature or pressure. A comms code with a refrigerant cause. | Occasional |
| A blown fuse on the outdoor inverter board | Toshiba name the 25 A and 3.15 A fuses on the inverter board as the check when the outdoor unit never answers. The unit has power but its board does not. | Occasional |
| A loose or corroded terminal | Terminations at either end sit in enclosures that see temperature swings and, outdoors, damp. A degraded connection produces an intermittent fault. | Occasional |
| A control board fault at either end | Where this lands once the cable, fuses and protectors are eliminated. Toshiba’s test is the signal voltage between terminals 2 and 3 at the indoor unit: varying between 15 and 60 volts points at the outdoor inverter board, steady points at the indoor board. | Occasional |
What to try yourself
Read and record the full code before touching the power.
Toshiba’s technical handbook states that turning off the power supply before reading the fault codes clears the diagnostic memory; their current service manual says the codes are kept. You cannot tell which applies from the room, and on a communication fault this is exactly the moment people cycle the power and lose the evidence.Note both parts of the code. Communication appears more than once in Toshiba’s table, so the initial code matters for matching it.
If nothing at all is working — no lights, no response to the remote — that is a supply problem rather than this code. Toshiba’s owner checklist for a unit that does not operate is the main switch, the circuit breaker, a power cut and the timer.
If a breaker has tripped, reset it once only. A breaker that trips again has found something, and repeated resetting removes the protection rather than the fault.Ask whether anyone has been working outside or on the electrics recently. A comms fault appearing straight after usually has a simple explanation, and a cable disturbed during other work is Toshiba’s first cause.
Look at the outdoor unit. If it is smothered by planting, a cover or debris, or has been running in strong heat, clear the space around it — a protector opening on high pressure is on Toshiba’s own list for this code.
Now try a power cycle, having already recorded the code. If it returns, call an engineer and hand over both the code and what you have eliminated.
Get an F-Gas certified heat pump engineer to look at your Toshiba 01 - 04
We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What it costs to fix
Typical repair cost
£0–£400
Time on site
40 minutes
Nothing if a power cycle cleared a transient. An engineer visit to trace a cable fault or replace a fuse, more if a protector has opened for a refrigerant reason, and more again if a control board needs replacing.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Toshiba fault codes
- 01 - 11Get it checkedAn indoor fan motor problem on the RAS domestic range. Read as a pair — initial code 01, detail code 11.Related: same brand
- 03 - 1EGet it checkedHigh compressor discharge temperature. Toshiba group it with the locked rotor and overcurrent codes, and it points at the refrigerant circuit.Related: same brand
Own a Toshiba air conditioner? Save it and its codes come first next time.
Related guides
Common questions about Toshiba 01 - 04
Can I not just turn it off and on?
You can, but read the code first. Toshiba’s handbook warns that powering down clears the diagnostic memory, and although their current service manual says the newest units keep the codes, you cannot tell from the room which you have. Read, write it down, then cycle.
The indoor unit works, so the outdoor one must have power.
On a Toshiba domestic split, yes — which is the opposite of what people expect. One supply feeds both units, arriving at the outdoor unit as standard and reaching the indoor unit over the connecting cable, or the other way round on installations wired with the optional indoor supply. If the indoor unit is lit, the supply is on. The code is telling you the outdoor unit is not answering, and Toshiba’s reasons for that are the cable, a fuse or a protector in the outdoor unit, or a board.
Why does communication appear as more than one code?
Toshiba list indoor to outdoor communication in more than one place in the RAS table, including rows that also take in the compressor thermostat. They describe slightly different detection paths for a related condition, which is why matching the initial code as well as the detail code matters.
It happens on hot days only.
Worth reporting, because that pattern points somewhere specific. Thermal movement on a marginal connection, or a component that only misbehaves at temperature, both produce heat-dependent intermittent faults — and a fault that only appears in particular conditions is much easier to find if the engineer knows the conditions.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.