Toshiba 03 - 1E fault codewhat it means and how to fix it
High compressor discharge temperature. Toshiba group it with the locked rotor and overcurrent codes, and it points at the refrigerant circuit.
Take care
Get an F-Gas certified heat pump engineer to look at your Toshiba 03 - 1E
We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What 03 - 1E means
Toshiba publish detail code 1E under initial code 03 as a high compressor discharge temperature, and it belongs to the most serious group in their domestic table. The discharge line is the pipe leaving the compressor, carrying refrigerant that has just been compressed and is therefore hot by design. When that temperature climbs beyond what the system expects, something in the refrigerant circuit is not behaving, and the system stops the compressor to protect it. The protection matters, because sustained high discharge temperatures break down the oil that keeps a compressor alive, and a compressor that loses its lubrication does not recover.
So this is a code to respect rather than reset repeatedly. The usual reasons a discharge temperature runs high are all circuit conditions rather than component failures. An undercharged system is the classic one, because refrigerant returning to the compressor is what cools it — less gas means less cooling and a hotter discharge. A restriction in the circuit, such as an expansion valve not opening properly or a blockage, does the same. So does anything that stops the outdoor unit rejecting heat, which is where the one owner-visible cause lives: a unit smothered by planting, fencing, a cover, or fins packed with debris cannot get rid of the heat it has collected, and everything downstream runs hotter.
Look at the codes Toshiba group alongside it, because they tell the same story. Under the same initial code 03 they publish a compressor locked rotor current protection, a compressor current remaining too high after current release, and a fault where the indoor heat exchanger changes temperature in the wrong direction — which is a reversing valve or mode problem. Under initial code 02 sit the TE, TS and Td sensor faults, which are the sensors that measure these very temperatures. All of it points into the sealed refrigerant circuit, and all of it is certified work. Toshiba’s current domestic manuals are written for R32 or R410A units, and both are fluorinated gases under the same certification rules, so nothing about the refrigerant changes who may open the circuit.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Low refrigerant charge | The classic cause. Returning refrigerant is what cools the compressor, so an undercharged circuit runs hot on the discharge side. It also implies a leak, since the circuit is sealed. | Common |
| The outdoor unit unable to reject heat | Planting, fencing, covers or packed fins. The one cause you can see and the one you can do something about before calling anybody. | Common |
| A restriction in the refrigerant circuit | An expansion valve not opening correctly, or a blockage. Produces high discharge temperatures with a nominally correct charge. | Occasional |
| A discharge temperature sensor fault | Toshiba publish Td and TE sensor faults separately. A sensor reading high produces this protection with a perfectly healthy circuit. | Occasional |
| A compressor problem | The serious end, and the reason the protection exists. Toshiba group locked rotor and sustained overcurrent codes alongside this one. | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£200–£1,100
Time on site
3 hours
A leak trace and recharge or a sensor at the lower end. A compressor replacement at the top, which on an older split is often more than the system is worth.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Toshiba fault codes
- 01 - 11Get it checkedAn indoor fan motor problem on the RAS domestic range. Read as a pair — initial code 01, detail code 11.Related: same brand
- 01 - 04Get it checkedIndoor to outdoor communication on the RAS range. Toshiba’s own list starts with the connecting cable and includes the outdoor unit’s protectors — and read the code before you switch anything off.Related: same brand
Own a Toshiba air conditioner? Save it and its codes come first next time.
Related guides
Common questions about Toshiba 03 - 1E
Can I keep resetting it and carrying on?
No, and this is the code where that matters most. High discharge temperatures degrade the oil that lubricates the compressor, and the protection exists to stop that. Clearing it and running on turns a repairable circuit fault into a compressor replacement.
Is there anything I can check first?
One thing, and it is genuinely worth doing: the space around the outdoor unit. If it cannot reject heat because planting has grown over it, a fence has gone up too close, a cover was left on, or the fins are packed with debris, then everything downstream runs hot. Clear it and note whether it improves.
Does this mean I need refrigerant?
It may, and low charge is the classic cause — but a sealed circuit that is low has leaked, so the answer is a leak trace rather than a top-up. It could equally be a restriction, a sensor, or the outdoor unit being smothered, and only gauges on the circuit will tell you which.
Why can no one just do this quickly?
Because diagnosing it means putting gauges on a sealed refrigerant circuit, and handling that gas requires certification by law. It is not padding on the invoice — recovery, leak detection and recharge are all restricted work, and the certification exists because of what these gases do when released.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Trade body guidance
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.