Baxi E125 fault codewhat it means and how to fix it

Get it checkedBoilerEvery three-digit Baxi. Selector-switch facia (E1 then 25, no reset offered): Duo-tec Combi HE and HE A, Platinum, Platinum+, Megaflo System HE A. Digital display with R (reset one to three seconds): Duo-tec 2, Compact, 600, 800, Assure, Megaflo System, EcoBlue. The Combi 2 uses E.01.17 and H.01.18 for circulation.Last updated

Baxi's primary circulation fault, decided by two temperature tests the manuals spell out. Pump, air or a blocked filter; the pressure is usually fine.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

Get a Gas Safe registered engineer to look at your Baxi E125

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Can you hear or feel the pump?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

Nothing — no hum, no vibration

The pump is not running. Seized, or not being fed by the board.

Engineer job. On the 600 and 800 the flow checks for 230 V at the pump connector before condemning it.

It hums but the radiators stay cold

Running but not moving water: air in the pump or an obstruction. The two things Baxi's flow says to check.

Bleed the system; if that does not clear it, an engineer will vent the boiler and check the filter and pump.

It started after a radiator was changed or the system drained

Almost certainly air. Baxi's user guide says the de-aeration function must be repeated after any partial drain.

Bleed all radiators, check the pressure, reset once on a digital-display boiler.

What E125 means

E125 is "Circulation Fault (Primary Circuit)" on the selector-switch Baxis and "Circulation fault (primary)" on the digital-display ones, and Baxi are unusually specific about how the board decides it has one. The Duo-tec Combi HE A manual: "E125 is displayed in either of two situations: i) If within 15 seconds of the burner lighting the boiler temperature has not changed by 1°. ii) If within 10 minutes of the burner lighting the boiler temperature twice exceeds the selected temperature by 30°. In these instances poor primary circulation is indicated." The 600 and 800 manuals keep both tests and widen the first window to "between 15 and 30 seconds".

Two opposite symptoms, one diagnosis: no temperature change means the water at the sensor is not moving; repeated overshoot means it is moving too slowly to carry the heat away. What the reader should do differs by generation. On the Duo-tec HE and Platinum the user guide puts E125 among the codes that "indicate faulty components. You should make a note of the displayed error code and contact your installer or service engineer" — no reset is offered.

On the 600, 800 and Compact it is in the list of codes relit by "pressing the Reset button for 1 to 3 seconds". The 600 Combi fault-finding flow for 109 and 125 is short: "System fault — correct. Ensure that the boiler and system are fully vented. Check flow temperature sensor connections and position", with the sensor's cold resistance given as about 10 kΩ at 25 °C. Pressure is not on that list, because a system can be at 1.5 bar and still not circulating.

What causes it

Causes of the Baxi E125 fault code, most common first
CauseWhat is actually happeningHow likely
Pump failed or running slowThe most common cause on a boiler over eight years old. Baxi's pump on the 600 and 800 is part 7684006 and the head alone (7686336) can be changed on some; a failing pump often hums without turning.Common
Air in the boiler or systemBaxi's stated remedy is to ensure the boiler and system are fully vented. Air at the top of the heat exchanger or in the pump housing stops flow past the sensor even with the pump spinning.Common
Blocked filter or sludged systemA magnetic filter that has not been cleaned, or a system without one that has sludged, strangles the flow the pump can deliver. Overshoot at the sensor is the typical result.Common
Flow sensor connection or positionBaxi's flow checks the flow temperature sensor connections and position. A sensor that has come loose from its pocket reads slowly and the board sees "no change in 15 seconds" on a perfectly good system.Occasional
Closed valves or a stuck diverterEvery radiator valve shut, a system isolation valve left closed after work, or a combi diverter that has not moved over to the heating port. The pump has nowhere to push.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£500

Time on site

1 hour

Bleeding costs nothing. Filter clean £60–£90 at a service. Pump head (Baxi 7686336) £150–£250 fitted; pump assembly (7684006) £200–£320. Power flush £300–£500.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Magnetic system filter, 22mm

MAG-22£65–£120Plumbing merchant

Price checked 28 September 2026

Baxi / Potterton / Main NTC temperature sensor (flow, return or DHW)

7207471£18–£45Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi / Potterton / Main pump assembly

7684006£120–£240Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi / Potterton / Main diverter valve motor

7216534£45–£95Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Baxi boiler? Save it and its codes come first next time.

Common questions about Baxi E125

Can I reset E125?

On the 600, 800, Compact and Assure, yes — Reset for one to three seconds, and Baxi list 125 among the codes that relights. On the selector-switch Duo-tec HE and Platinum the user guide offers no reset for E125 and says to note the code and contact your installer.

The pressure is fine, so why a circulation fault?

Because E125 is a temperature test, not a pressure one. Baxi's board watches whether the flow temperature changes in the first seconds after ignition and whether it overshoots later. Plenty of water sitting still fails both tests.

What is the difference between E125 and E109 or E193?

E109 (digital display) and E193 (selector switch) are pre-circulation faults, decided before the burner lights. E125 is decided after ignition from the temperature response. Same underlying problem, different moment of detection.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead