Glow-worm F.85 fault codewhat it means and how to fix it

Get it checkedBoilerF.85 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F85 on Ultracom2, Betacom 24a/28a and Betacom2 · not in the Ultracom, Flexicom, Ultrapower or CI tablesLast updated

Flow and return sensors reading identically because both are clipped to one pipe, or one is on the wrong pipe or unplugged. An installation fault, corrected by refitting the sensors.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.85

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.85 means

Where F.84 catches sensors that have been swapped, F.85 catches sensors that have been put in the same place. Glow-worm's Energy7 and Ultimate3 manuals define it as "Fault: Temperature sensor — the flow and/or return temperature sensors have been installed on the same pipe/incorrect pipe; temperature sensor not connected or is connected incorrectly". The Compact manual's heading is blunter, "flow and return temperature sensors have been installed incorrectly", with one measure: check that each is on the correct pipe.

The two-digit Ultracom2, Betacom 24a/28a and Betacom2 have F85 as "flow and return heating sensors fault — flow and return heating temperature sensor connected to same tube". Two readings that track each other exactly tell the board it has lost the information it uses to protect the heat exchanger, so it stops. Like F.84 this is a consequence of work on the boiler rather than a fault that develops in service, and Glow-worm give no householder step for it on any range; the homeowner page does not list it.

An engineer checks that each thermistor is on its own pipe in the position the installation manual shows, that both plugs are in the right positions on the board, and that neither was left off after a heat exchanger or pipe change. There is no 85 in the Ultracom, Flexicom, Ultrapower or CI tables.

What causes it

Causes of the Glow-worm F.85 fault code, most common first
CauseWhat is actually happeningHow likely
Both thermistors on one pipeGlow-worm's "installed on the same pipe". Two identical clip-on sensors and two adjacent pipes; after a heat exchanger or hydraulic block change one is clipped beside the other.Common
One sensor unplugged or in the other's socket"Not connected or is connected incorrectly". A plug left off after a repair, or the two plugs crossed at the board, gives readings the board cannot reconcile.Occasional
Sensor on a pipe that is not the flow or the returnGlow-worm's "incorrect pipe" — a bypass or the hot water side, which follows neither the flow nor the return. Read the position from the installation manual rather than from where the clip happens to fit.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£130

Time on site

30 minutes

A call-out fee, £80–£130, to refit the sensors. A thermistor is seldom needed.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm flow or return temperature sensor (clip-on NTC)

£12–£35Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?