Skip to content
FaultcodeCheck

Glow-worm F.88 fault codewhat it means and how to fix it

Get it checkedBoilerEnergy, Energy7, Ultimate3, Easicom3, Betacom3/4 and Compact only — not printed for any earlier Glow-wormLast updated

The gas valve assembly is not connected, is connected wrongly, or its harness is shorted. The board found this on its self-check, so no gas has been released and nothing lights.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.88

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.88 means

Glow-worm print F.88 as "Fault: Gas valve assembly" on the Energy7, Ultimate3, Easicom3, Betacom3 and 4 and Compact, with the causes "gas valve assembly not connected or it is connected incorrectly, short circuit in the wiring harness". It is the sibling of F.87 for the igniter and F.89 for the pump: the newest boards test each actuator is present and sane before every start, and F.88 is that test failing for the valve. It is not F.61 — that is a control fault found while the valve is being driven — and it is not F.62. Nothing is passing gas; the valve has not been asked to open, and the board will not ask it while the circuit reads wrong.

Practically, F.88 turns up in two situations. After a repair, where the valve plug has been left off or pushed on to the wrong header — and after years of service, where the harness has chafed through against the gas valve body or the casing.

A valve whose coil has gone open circuit shows the same signature, and Glow-worm's checks for the engineer run in that order: the connection, the harness, then the assembly. This is a current-range code only; the two-digit Ultracom2 and Betacom2 tables end at F86 and Err, and the older Ultracom lists at F77. Every Glow-worm user guide for the ranges that show it reserves it for a competent person, and there is nothing to be gained from a reset: the board repeats the same check and finds the same missing valve.

What causes it

Causes of the Glow-worm F.88 fault code, most common first
CauseWhat is actually happeningHow likely
Valve plug off or on the wrong headerGlow-worm's first cause, usually after a service or a board change. The plug is a small keyed connector on the valve body and it is easy to leave unseated.Common
Harness to the valve chafed or shortedThe loom runs past the gas valve body and the burner door, and a conductor worn through to earth trips the presence check. Glow-worm's second cause.Occasional
Valve coil open circuitThe assembly itself has failed electrically. Reached last in Glow-worm's checklist, and replaced as a unit.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£400

Time on site

1 hour

Free if a plug was off. Harness repair £90–£150. Gas valve assembly £250–£400.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm gas valve assembly

£90–£200Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.88

Is this a gas leak?

No. The board has not opened the valve and will not while F.88 stands. If you can smell gas it is a separate matter for 0800 111 999, but this code does not itself mean gas is escaping.

F.61, F.62 or F.88 — what is the difference?

F.88 is the valve not found on the self-check. F.61 is the valve present but its control circuit faulty when driven. F.62 is the valve failing to shut off cleanly. Glow-worm print all three as separate rows.

Cost?

A reconnection is trivial. A harness repair £90–£150. A gas valve assembly £250–£400 fitted, and it is the last thing an engineer should change.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?