Glow-worm F26 fault codewhat it means and how to fix it

Get it checkedBoilerGas valve motor on Ultracom2 cxi/sxi, Betacom 24a/28a and Betacom2 · gas valve stepper motor as F.26 on the Energy 35 Store · poor circulation on the early cxi · not on Ultracom, Flexicom, Ultrapower or the other F.xx rangesLast updated

F26 on a two-digit Ultracom2, Betacom 24a/28a or Betacom2 is the gas valve motor — disconnected or defective cables. On an early cxi, F26 is poor circulation. Engineer either way.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F26

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Which display are you looking at?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

F26 without a stop on an Ultracom2, Betacom 24a/28a or Betacom2

Gas valve motor — its cables or the valve. A gas fault.

Do not reset repeatedly. Book a Gas Safe registered engineer.

F26 on an early-2000s cxi with a flashing red light

Poor circulation — the water side, not the gas.

Check the pressure gauge and that radiator valves are open, reset once from the On/Off switch, and book an engineer if it returns.

What F26 means

On the two-digit boards — Ultracom2 cxi and sxi, Betacom 24a and 28a, Betacom2 — Glow-worm's installation manuals give F26 as "fault in gas valve motor — disconnected or defective cables", with three measures: check the gas valve connections, check the operation of the gas valve, and check the operation of the condensate pump if one is fitted. The Ultracom2 trade table shortens it to "fault in gas valve". It shares its cause list with F77 on the same boards, and an engineer treats the two together: a gas valve whose motor the board cannot drive, or cannot hear back from, is replaced as an assembly, and a lead pulled during a service is put back.

On the early-2000s cxi the trade table has F26 as "poor circulation", the twin of its F25 — water not moving through the heat exchanger, the fault covered on the F.23 and F.24 pages — which has nothing to do with gas.

The Ultracom, Flexicom and Ultrapower have no F26. Among the current F.xx ranges only the Energy 35 Store lists F.26 — "Fault: gas valve without function", the stepper motor not connected, a plug on the PCB not home, a break in the harness or the motor itself defective — and it is the same part seen from the same side; the Energy, Ultimate, Easicom, Betacom3/4 and Compact report their gas valve through F.61, F.62 and F.88 instead, so an owner of one of those seeing what looks like F.26 should read the display again. The gas valve version has no householder step in any Glow-worm guide and should not have: a valve that does not answer its board is a gas-carrying part, and the boiler staying off is the correct outcome until an engineer has proved it.

What causes it

Causes of the Glow-worm F26 fault code, most common first
CauseWhat is actually happeningHow likely
Gas valve lead disconnected or damaged — two-digit boardsGlow-worm's stated cause: "disconnected or defective cables". A plug knocked off the valve during a service, or a lead chafed on the casing, and the board cannot drive the motor.Common
Poor circulation — early cxiOn that one range F26 is the water side: pump, diverter valve, air or low pressure. The checks are those for F.23 and F.24.Common
Gas valve motor failed — two-digit boardsThe measure "check the operation of the gas valve". A motor that no longer moves the valve is replaced with the valve as one assembly; it is not serviced.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£320

Time on site

1 hour

A lead reconnected £80–£130. A gas valve assembly on a two-digit board £250–£320 fitted. A circulation fault on a cxi £80–£300 depending on the part.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Glow-worm gas valve assembly

£90–£200Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?