Vaillant F.23 fault codewhat it means and how to fix it
The gap between flow and return temperature is too wide. Vaillant call it water shortage, and it nearly always means the pump is not moving enough water.
Take care
What F.23 means
Vaillant describe F.23 as water shortage, with the temperature difference between the flow and return sensors being too large. Understanding what the appliance is actually measuring makes this code much easier to interpret. Water leaving the heat exchanger and water returning to it should be reasonably close together, because water moving at a healthy rate picks up heat gradually as it passes through. When flow slows down, each unit of water sits in the exchanger longer and gets much hotter, so the split between the two sensors widens sharply. The appliance watches that gap and stops when it exceeds what it considers safe. Vaillant's own documentation lists a blocked or defective pump, insufficient pump output, and flow and return sensors that have been interchanged. That last one matters: if F.23 appears immediately after somebody has worked on the appliance, the sensors being swapped over is a genuinely likely explanation and is quick to correct.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Pump blocked or output too low | Named first in the Vaillant documentation. A pump that has stiffened after standing idle, or one set to too low a speed for the system it is on. | Common |
| Air in the primary circuit | An air pocket interrupts flow and produces exactly this widening split. Frequently follows a refill that was done too quickly. | Common |
| Flow and return sensors interchanged | Listed explicitly by Vaillant. If the fault started straight after a repair or a sensor replacement, check this before anything else — it costs nothing to correct. | Occasional |
| Heat exchanger restricted by sludge | Magnetite narrowing the waterways reduces flow through the exchanger specifically, even when the radiators seem to circulate acceptably. | Occasional |
What to try yourself
Check the system pressure is 1.0 to 1.5 bar cold, and top up through the filling loop if it is not. Low pressure and poor flow travel together.
Open every thermostatic radiator valve fully so the pump has a proper path to circulate through.
Bleed the radiators, starting downstairs and finishing with the highest one in the property, then top the pressure back up.
Think back to whether anyone has worked on the boiler recently. If F.23 started immediately afterwards, mention the possibility of swapped flow and return sensors when you call — it is a five-minute fix if that is what it is.
Reset once with the reset button held for three seconds. If it returns, book an engineer rather than resetting repeatedly.
Get a Gas Safe registered engineer to look at your Vaillant F.23
Gas Safe Register engineers only. No obligation.
What it costs to fix
Typical repair cost
£120–£750
Time on site
40 minutes
Bleeding and repressurising is free. Swapping mis-fitted sensors back is a call-out charge of £80 to £140. A pump is £220 to £420 fitted and a chemical clean with a filter £400 to £750.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Central heating circulating pump
CH-PUMP-15-60£90–£180Plumbing merchant
Price checked 5 August 2026
Magnetic system filter, 22mm
MAG-22£65–£120Plumbing merchant
Price checked 5 August 2026
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Vaillant fault codes
- F.20Stop — call an engineerThe overheat thermostat has tripped because the boiler got too hot. It has shut down to protect itself and it should not be restarted repeatedly.Related: overheat and circulation
- F.24Get it checkedTemperature is rising faster than it should when the burner fires. That is a circulation problem caught a step earlier than an overheat.Related: overheat and circulation
- E9 219Stop — call an engineerThe boiler has overheated and the safety thermostat has tripped. Water is not carrying heat away from the exchanger, and it should not be run until that is fixed.Related: overheat and circulation
- L1Get it checkedThe boiler is not seeing enough water flow through it to run safely, so it has stopped. Usually a pump, an air lock, or a blocked filter.Related: overheat and circulation
- E02Get it checkedThe overheat thermostat has tripped. Almost always this means water is not moving through the appliance properly rather than that it is running too hot.Related: overheat and circulation
- A02Get it checkedThe safety limit thermostat has tripped on overheat. In practice this nearly always means water has stopped circulating properly.Related: overheat and circulation