Vaillant F.343 fault codewhat it means and how to fix it

Get it checkedBoilerecoTEC plus CS/1-5 (2022 onwards, three-digit display) with the multiple-flue conversion set and its air-mass flow sensor. No two-digit range has the sensor.Last updated

The air-mass flow sensor on a 2022 ecoTEC plus is giving a signal the board does not believe. Vaillant's causes are its plugs and harness, a dirty or failed sensor, or the PCB.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Vaillant properly.

Get a Gas Safe registered engineer to look at your Vaillant F.343

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.343 means

F.343 is the companion to F.342. Where F.342 is an air-mass reading that is real but outside the limits, F.343 is "the signal for the air-mass flow sensor is not plausible" — a reading the board rejects as impossible.

Vaillant's list is the sensor's own circuit and condition: the air-mass flow sensor plug loose or not plugged in; the plug on the PCB; an interruption in the wiring harness; "measurement discrepancy too high — air-mass flow sensor dirty: check the air-mass flow sensor for dirt"; "you exit the measuring range permanently — air-mass flow sensor defective: replace the entire air intake pipe"; and finally the PCB. The dirty-sensor line is the one with a story behind it. The sensor sits in the air intake, and everything the fan draws in passes it: dust from a workshop or a utility room, fluff from a tumble dryer sharing the space, cobwebs and insects from an outside terminal. A film on the sensing element skews the signal until the board stops believing it.

The sensor is part of the multiple-flue conversion set — the air intake pipe with a built-in non-return valve — so it is fitted where the boiler shares a flue, and it is replaced with the pipe rather than on its own. Unlike F.342, Vaillant's list for F.343 does not include the flue itself, so the page does not carry the CO flag; the boiler has simply lost a measurement it needs and stopped.

What causes it

Causes of the Vaillant F.343 fault code, most common first
CauseWhat is actually happeningHow likely
Sensor plug or PCB plug looseVaillant's first two items. Connectors on the air intake disturbed during a service or a filter clean.Common
Air-mass sensor dirtyVaillant's "measurement discrepancy too high". Dust or fluff drawn in with the combustion air coats the element; the check is to inspect it for dirt.Common
Wiring harness interruptedA break in the lead between the sensor and the board.Occasional
Sensor out of range permanently, or PCB defectiveVaillant's last two lines: replace the entire air intake pipe, or replace the PCB. Reached when the plugs, harness and cleaning have not restored a plausible signal.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£400

Time on site

1 hour

A plug reseat or a sensor clean is a call-out of £90 to £150. The air intake pipe with its sensor is priced on the part; a PCB is £250 to £400 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Vaillant main PCB (electronics box)

£160–£340Authorised Vaillant parts distributor

Price checked 28 September 2026

Vaillant wiring harness (plug-and-cable set to a sensor or actuator)

£20–£65Authorised Vaillant parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Vaillant F.343

Can I clean the sensor?

It is inside the boiler's air intake, which Vaillant restrict to a competent person, and the element is delicate. An engineer inspects it as part of the F.343 check.

How is F.343 different from F.342?

F.342 is a real air-flow measurement outside the limits — the fan or the flue. F.343 is a signal the board does not believe at all — the sensor or its wiring. The engineer's starting point is different for each.

Why do I keep getting it in a dusty room?

Because the boiler breathes that room's air unless its intake comes from outside through the flue. Keeping the space clean, or having the installer check the air supply arrangement, addresses the cause rather than the symptom.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.