myenergi zappi Bad Voltage Range

Get it checkedEV chargerzappi v2 and v2.1, single and three phase.Last updated

Code 31, shown with Over Voltage or Under Voltage. The mains supply is outside the range the zappi will charge on, so it has disconnected the car. The fault is upstream of the charger.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a registered electrician to look at the myenergi zappi properly.

What this means

Bad Voltage Range is code 31, and the screen usually adds which way it went, Over Voltage or Under Voltage. myenergi’s meaning is that the zappi has detected that the supply voltage is too high or too low and has disconnected the EV to protect it, and their action carries the same condition they attach to the PEN fault: unplug the EV, make sure that the fault has been removed, and then hold the button to reset. That condition is the important part. The installation manual gives the numbers: the nominal supply is 230 volts, and the zappi trips its output if the measured voltage is more than 12 per cent above or below that for five seconds — roughly 202 to 258 volts — showing Over Voltage! or Under Voltage!, and it resets automatically once the voltage returns to the acceptable range of 230 volts plus or minus ten per cent, which is also the rated supply range in the specifications.

When the mains sits outside that band there is nothing in the charger to fix; resetting into the same supply produces the same code. The cause is either the incoming supply itself, which the distribution network operator is obliged to keep between 216 and 253 volts, or the installation, where a long or undersized cable run to the charger drops enough voltage under 32 amps to trip the low end while the rest of the house reads normal — the IET have written about exactly this, because the open-PEN detection that BS 7671 permits works on the voltage at the charging point, and voltage drop in the installation’s own cable can take that below 207 volts and cause unwanted tripping on a supply that is perfectly healthy at the meter.

Over-voltage on a UK supply is most often seen in the middle of a sunny day on a street with a lot of solar exporting into the same substation. Under-voltage is more often the evening peak or the cable. Code 31 that appears at the same times of day is telling you which. A UK chargepoint disconnecting on voltage is also doing part of its job against a lost PEN conductor, which is why it will not simply ride through a bad reading.

What causes it

Causes of myenergi zappi Bad Voltage Range, most common first
CauseWhat is actually happeningHow likely
Supply voltage more than 12% from 230 V for five secondsmyenergi’s published trip point, with automatic recovery once the supply is back inside 230 V ±10%. Solar export in the daytime pushes streets high; evening demand pulls them low. The DNO owns this.Common
Voltage drop on the charger’s own circuitA long or thin cable from the consumer unit loses volts under full charging current, so the zappi sees Under Voltage while the house does not. The IET describe this as a known cause of unwanted open-PEN tripping; an installer can measure it.Common
A loose supply or neutral connectionVoltage that swings both ways or flickers points at a connection rather than the grid, and that is an electrician’s check with the circuit isolated.Occasional

What to try yourself

  1. Read the screen and note whether it says Over or Under, and what time it happened. The pattern is most of the diagnosis.

  2. Unplug the EV. Wait for the supply to settle, then press and hold the menu button to reset if the unit has not already reset itself — the installation manual says it resets automatically once the voltage is back inside 230 V ±10%. myenergi say to make sure the fault has been removed first, so a reset during the same conditions will not hold.

  3. If it recurs only under charging and the house voltage is fine, ask the installer to check the voltage drop on the charger circuit. That is a measurement at the zappi under load, not an owner job — and UK Power Networks ask owners to have their own equipment checked by the installer or an electrician before reporting a charger voltage issue to them.

  4. If it recurs at the same time of day, note the dates and times and report it to your distribution network operator. UK Power Networks describe the process: they check for known network problems, send an engineer, and if needed fit a recording device for two weeks.

Get a registered electrician to look at your myenergi zappi ev charger

We do not pass enquiries to a repair firm, so there is no form here. When you book a registered electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£0–£300

Time on site

15 minutes

Nothing when it is the grid; supply voltage is the DNO’s to investigate and correct. A cable upgrade on the charger circuit, if the drop is the cause, is typically £150 to £300.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Trade body guidance

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?