myenergi zappi Lock Failure
Code 23, and the fix is counter-intuitive: push the plug further in to release it. Untethered zappis only.
Take care
What this means
Lock Failure is code 23, and myenergi describe it as the socket lock actuator being unable to lock or unlock the inserted plug as expected. It applies only to untethered units — the ones with a bare socket you plug your own cable into — because a tethered zappi has no socket lock to fail. What makes it worth its own page is that myenergi's remedy is the opposite of what anybody does instinctively. Their stated causes are that the plug is not fully inserted, or is twisted or pulled. Their stated action is to push the plug fully in to release it, then press and hold the button to reset.
So when the cable will not come out, the answer is to push it in harder before pulling. That is not a trick; it is mechanical. The actuator drives a pin into a recess in the plug, and it can only withdraw cleanly if the plug is sitting square in the socket. A plug that is half-seated, or being pulled sideways by the weight of a heavy cable hanging off it, jams the pin against the side of the recess. Pushing the plug home takes the load off the pin and lets it retract. The weight point is worth acting on rather than just knowing. A 32 amp cable is heavy, and left dangling it applies constant leverage to the plug. Looping it over the unit or into a holster so the connector is not carrying the cable's weight prevents a good proportion of these.
Two related messages sit alongside this one in myenergi's table without numbers, and both look similar from the driveway. Unknown Cable means the unit has not recognised the cable — myenergi say to use genuine IEC 62196-2 compliant plugs, note the supported ranges of 32, 20 and 13 amps, and add that the unit re-tests automatically after five seconds. Pilot problem is an issue with the control pilot signal between the zappi and the car, which also auto-retests after five seconds. For both, myenergi's advice if it persists is the same and it is worth doing here too: unplug, check for dirt in the plug, and retry. Grit in a driveway socket is a genuinely common cause of all three.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| The plug is not fully inserted | myenergi’s first stated cause. A plug that feels seated can still be a few millimetres short, which is enough to stop the lock pin retracting cleanly. | Common |
| The plug is twisted or being pulled | Also stated by myenergi. The weight of a 32 amp cable hanging from the socket applies constant leverage, which is enough to bind the actuator. | Common |
| Dirt or grit in the socket | myenergi give checking for dirt in the plug as the remedy for the neighbouring cable and pilot messages, and it applies here for the same reason — a driveway socket collects debris. | Common |
| A worn or damaged plug | The recess the lock pin engages wears over years of daily use. A cable that has started failing on one charger and works on another points here. | Occasional |
| A failed lock actuator | The genuine hardware case, and the least common. It shows as the fault appearing with every cable and persisting after the plug is properly seated. | Occasional |
What to try yourself
Push the plug fully into the socket. This is myenergi’s published action and it is the opposite of the instinct to pull — seating the plug is what lets the lock pin retract.
Take the weight of the cable while you do it, so the connector is not being levered downwards by several kilos of hanging cable.
Press and hold the menu button — the round button with three lines — to reset, which is the second half of myenergi’s stated action.
If it releases, look into the socket and the plug for grit or debris before using it again. myenergi give dirt in the plug as the cause of the neighbouring cable and pilot messages.
Try a different cable if you have one. A fault that follows the cable is a worn plug; a fault that stays with the charger is the actuator.
If the cable is still held after seating and resetting, contact myenergi rather than forcing it.
Do not pull hard on a locked connector or attempt to release the mechanism with a tool. You will damage the socket, and the cost of a new socket assembly is considerably more than a support call.
Get a registered electrician to look at your myenergi zappi ev charger
We do not pass enquiries to a repair firm, so there is no form here. When you book a registered electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What it costs to fix
Typical repair cost
£0–£180
Time on site
15 minutes
Nothing in most cases, because the published remedy is a technique rather than a repair. A charging cable if the plug has worn, or a manufacturer visit if the actuator has genuinely failed.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related myenergi zappi fault codes
- Pilot problemUsually simple to fixThe zappi cannot read the control pilot signal on the cable to the car. It retests every five seconds; myenergi’s advice is to unplug, check the plug for dirt and try again.Related: lock and connector
- Unknown CableUsually simple to fixAn untethered zappi could not identify the rating of the cable plugged into it. Only genuine 13, 20 or 32 amp Type 2 cables are recognised; the unit retests after five seconds.Related: lock and connector
- PEN FaultStop — call an engineerCode 29. The protection against loss of the supply earth-neutral conductor has operated, and myenergi tell you to remove the fault before resetting.Related: same brand
- PE FaultStop — call an engineerCode 25. myenergi say the earth is either disconnected or its impedance is too high — a problem in the installation rather than in the charger.Related: same brand
- SelfTest FailedGet it checkedCode 27, searched as A27. The built-in protection devices could not be tested, or failed the test, before a charge. myenergi’s action is a reset; they do not say it cannot be repaired.Related: same brand
- Charge BlockedUsually simple to fixNot a fault. The car keeps asking to charge after it already reported complete, and the zappi has stopped answering.Related: same brand
Own a myenergi zappi ev charger? Save it and its codes come first next time.
Related guides
Common questions
The cable is stuck. Do I really push it in?
Yes, that is myenergi’s published remedy: push the plug fully in to release it, then press and hold the button to reset. The lock pin sits in a recess in the plug and can only withdraw when the plug is square in the socket, so seating it properly is what frees it.
Why does this only happen to me and not my neighbour?
Because the neighbour probably has a tethered unit. myenergi note this fault applies to untethered units only — a charger with its own permanently attached cable has no socket lock to fail.
What about Unknown Cable and Pilot problem?
Different messages in the same area of myenergi’s table, both without numbers. Unknown Cable means the plug was not recognised, and myenergi ask for genuine IEC 62196-2 compliant plugs at 32, 20 or 13 amps. Pilot problem is the control pilot signal between the charger and the car. Both re-test automatically after five seconds, and for both myenergi say to unplug, check for dirt in the plug and retry.
Can I stop it happening again?
Largely, yes. Hang the cable so its weight is not pulling on the connector, keep the socket free of grit, and push the plug home firmly rather than resting it in. Two of myenergi’s three stated causes are about how the plug is sitting, and both are within your control.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.