myenergi zappi PEN Fault

Stop — call an engineerEV chargerLast updated

Code 29. The protection against loss of the supply earth-neutral conductor has operated, and myenergi tell you to remove the fault before resetting.

Get a registered electrician to look at your myenergi zappi ev charger

We do not pass enquiries to a repair firm, so there is no form here. When you book a registered electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What this means

PEN Fault is code 29, and myenergi describe it as the internal protection against loss of the PEN conductor on the electricity supply having tripped. The action they publish is worth reading carefully because of a clause most owners skip: unplug the EV, make sure the fault has been removed, then press and hold the button to reset. Make sure the fault has been removed is doing all the work in that sentence. It is myenergi saying that the condition is outside the charger, that resetting does not address it, and that if it is still present the unit will simply trip again. What has happened is that the charger has detected a voltage condition consistent with the loss of the combined protective earth and neutral conductor on the incoming supply.

On the common UK domestic arrangement, that conductor doubles as the earth for the whole installation, and if it fails, anything earthed in the property can rise to a dangerous voltage — including a car on the drive with a cable plugged into it. That is why chargepoints are required to protect against it. myenergi list built-in PEN protection as meeting BS 7671:2018 Amendment 1:2020, and their installation manual explains the choice the regulation offers — an extra earth electrode or a device that detects the fault and disconnects — and that because the zappi has the detection built in, no earth electrode is needed with it. They also describe what happens when it operates: the zappi becomes completely isolated from the input supply, so all conductors present at the output socket or cable, including protective earth and control signals, will be safe, removing any risk of potential electric shock. The installation manual’s version of the reset is more specific than the user manual’s: check the continuity of the earth cable, then press the menu button for three seconds.

There is a documentation discrepancy worth knowing about, because it affects what you will find when you look this up. The June 2022 manuals print code 29 against two different messages in the same table — RCD Tripped, described as the internal earth-leakage protection having tripped, and PEN Fault — and the December 2022 and July 2023 revisions carry only PEN Fault at 29, with RCD Tripped gone from the table altogether, although the installation manual still says the display shows RCD Tripped! when the RCD operates. Both describe a protection device operating and both require the fault to be cleared before resetting, so the practical answer is the same, but if your manual and your display disagree, that is why.

What causes it

Causes of myenergi zappi PEN Fault, most common first
CauseWhat is actually happeningHow likely
A voltage excursion on the incoming supplyWhat open-PEN detection watches for. Because it is measuring the supply rather than the charger, it can operate during a network disturbance and affect more than one house at once.Common
Earth leakage in the charger, cable or vehicleThe other message the June 2022 manuals print at code 29 — RCD Tripped, the internal earth-leakage protection having operated. Leakage anywhere in the charging path produces it.Occasional
Repeated tripping at particular times of dayNot a separate cause but a pattern worth recording. Supply voltage varies through the day, so a trip that always happens at the same time points at the supply rather than the equipment.Occasional
An actual loss of the supply PEN conductorThe condition the protection exists for, and a genuinely dangerous one. This is a distribution network operator matter and not something to work around.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£260

Time on site

1 hour

Nothing if the cause is on the supply side, which is your network operator’s to resolve. An electrician’s visit to establish which side it is coming from, and more if leakage is found in the installation.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions

What does "make sure the fault has been removed" mean in practice?

It means establish why it tripped before pressing reset. myenergi are telling you the condition is outside the charger, so a reset with the condition still present will simply trip again. In practice that means noting when it happens, checking the app for a voltage record, and getting an electrician or your network operator involved rather than resetting nightly.

Why does my manual call code 29 something different?

Because myenergi have used the number for two messages. The June 2022 user and installation manuals print both RCD Tripped and PEN Fault at code 29 in the same table; the December 2022 and July 2023 user manuals keep only PEN Fault. Both are a protection device operating and both carry the same instruction to clear the fault before resetting, so the practical answer does not change.

Is my car in danger?

Not once the protection has operated, which is the point of it. myenergi publish that in a PEN fault the zappi becomes completely isolated from the input supply, so every conductor at the output — including protective earth and control signals — is safe. The hazard is the condition it detected, and the unit has removed you from it.

Who do I call?

Start with the installer or an electrician, because they can establish whether the trip is coming from the supply or from the installation. If it turns out to be supply voltage, that is your distribution network operator’s to fix, and they will normally want to monitor over several days rather than take a single reading.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.