Usually simple to fixEV chargerUntethered zappi v2 and v2.1 only.Last updated

An untethered zappi could not identify the rating of the cable plugged into it. Only genuine 13, 20 or 32 amp Type 2 cables are recognised; the unit retests after five seconds.

Before you start

This one is usually safe to look at yourself. Do not remove any panel that is held on with screws or clips — everything below is done from the outside of the ev charger.

What this means

An untethered zappi has to be told what cable it is wearing, and the cable tells it through a resistor inside the plug that encodes the current rating. Unknown Cable is the message when that value does not match anything the zappi expects. myenergi’s definition is that the zappi has detected an unknown EV cable, on untethered units only, and their remedy is a specification: make sure you are using genuine IEC 62196-2 compliant plugs, with the supported range given as 32, 20 and 13 amps.

As with the pilot message there is no reset to perform; the zappi will automatically retest the cable after five seconds, and if the issue persists their advice is to unplug the cable, check for dirt in the plug and try again. The two things that produce it are a cable that genuinely is not compliant, which is common among the cheapest online listings and among adapters, and a compliant cable whose proximity pin is not making contact because the plug is dirty, wet or not fully seated.

Since the rating the cable reports is what the zappi uses to cap the current it offers, this check matters: a cable that reports nothing might be one that would report wrongly, and the Overload code is what happens when a cable’s claim and its construction disagree. A tethered zappi has no socket and cannot show this message; if you have one and think you have seen it, look again at the screen.

What causes it

Causes of myenergi zappi Unknown Cable, most common first
CauseWhat is actually happeningHow likely
A non-compliant cable or adaptermyenergi’s stated cause. The coding resistor is missing or wrong, so the zappi cannot place it at 13, 20 or 32 amps.Common
Dirt, water or poor seating at the zappi socketThe proximity pin that carries the rating is small. Their published check for dirt in the plug is aimed at this.Common
A damaged plug at the zappi endThe coding resistor lives in the plug body. A plug that has been dropped or crushed can lose it while the cable still works elsewhere.Occasional

What to try yourself

  1. Unplug the cable from the zappi socket, check the plug face for dirt or moisture, dry it and push it fully home. Wait five seconds for the retest.

  2. Check the cable’s markings for EN 62196-2 and a current rating of 13, 20 or 32 A. A cable without a rating marked is the likely cause.

  3. Try a known compliant cable if one is available. If it is recognised, the original cable is the fault and should be replaced rather than persuaded.

Get a registered electrician to look at your myenergi zappi ev charger

We do not pass enquiries to a repair firm, so there is no form here. When you book a registered electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£0–£120

Time on site

5 minutes

Nothing if it is dirt. A compliant 32 A Type 2 cable is £60 to £120.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?