Vaillant F.9998 fault codewhat it means and how to fix it

Get it checkedHeat pumparoTHERM plus with uniTOWER plus or hydraulic station indoor units, and aroTHERM split with its VWL IS hydraulic station — both carry F.9998 in the indoor unit’s fault table. The earlier aroTHERM monobloc (VWL /2) does not: its eBUS fault is F.685, "Communication fault: eBUS — the product is not connected to the control; polarity inverted".Last updated

The heat pump has lost its eBUS connection to the controllers and wiring centre. Vaillant name an unconnected or miswired eBUS cable and an outdoor unit without supply voltage as the causes.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get an F-Gas certified heat pump engineer to look at the Vaillant properly.

What F.9998 means

F.9998 is the mirror image of the controller’s F.511. Where F.511 is the sensoCOMFORT saying it cannot hear the heat pump, F.9998 is the heat pump saying it cannot hear anything on the eBUS — Vaillant UK describe it as a communication fault between the heat pump and all eBUS controllers and wiring centres. The uniTOWER plus appendix gives two causes: the eBUS cable is not connected or is connected incorrectly, and the outdoor unit is without supply voltage. That second cause is the one an owner can do something about, because the outdoor unit has its own isolator and its own breaker, and either being off produces this code.

Vaillant’s owner-facing page goes much further and its list is worth knowing about even though every item on it is installer territory: mains voltage outside tolerance, a fault on the installer PCB, wiring faults between the heat pump and its interface, between the interface and the VR 71 wiring centre, and between the VR 71 and any wireless receivers, reversed polarity on the eBUS at any terminal, cable of insufficient diameter — Vaillant specify a minimum of 0.75 mm² twin core — induced current from mains cables run closer than 120 mm, the wrong cable type, since twisted multicore is not permissible, shielded cable that has not been suitably earthed, and finally a faulty HMU.

Read as a whole, that list says F.9998 is very often an installation-quality fault rather than a failed component, which is why it tends to appear on newly commissioned systems, after an electrician has been in, or when a wiring centre has been disturbed.

What causes it

Causes of the Vaillant F.9998 fault code, most common first
CauseWhat is actually happeningHow likely
Outdoor unit without supply voltageVaillant’s published cause and the one to check first: an isolator switched off, a breaker tripped, or a power cut that has not restored both units.Common
eBUS cable not connected or connected incorrectlyVaillant’s other published cause. Reversed polarity at any terminal, a loose core, or a connection disturbed during other work.Common
Wrong cable or a poor routeVaillant rule out twisted multicore, require at least 0.75 mm² twin core, and want 120 mm separation from mains cables. Installations that break these rules produce intermittent F.9998.Occasional
Installer PCB or HMU faultThe component end of Vaillant’s list, reached after the wiring and the supply have been proven.Occasional

What to try yourself

  1. Check the outdoor unit has power. There is normally a rotary isolator on the wall near it and a dedicated breaker in the consumer unit; either being off is one of Vaillant’s two published causes.

  2. Check the indoor unit and the wiring centre — usually a VR 71 box near the cylinder — are also powered and have not been switched off during other work.

  3. Think about recent visits. An electrician, a new socket, a smart thermostat installation or anyone working in the cupboard can disturb an eBUS terminal.

  4. Ring your installer with the code. Everything else on Vaillant’s list — polarity, cable type, separation from mains, the installer PCB — is theirs to check.

    Do not open the wiring centre or either unit to inspect eBUS terminals. Mains terminals sit in the same enclosures.

Get an F-Gas certified heat pump engineer to look at your Vaillant F.9998

We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£90–£300

Time on site

15 minutes

Nothing if an isolator was off. An installer visit to trace the eBUS fault is typically £90 to £180, and rerunning a badly routed cable is a few hours’ labour. An installer PCB is the expensive outcome.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Vaillant heat pump? Save it and its codes come first next time.

Common questions about Vaillant F.9998

What is the difference between F.9998 and F.511?

Direction. F.511 is shown by the sensoCOMFORT controller when it cannot reach the heat pump control module. F.9998 is shown by the heat pump when it has lost the eBUS to all its controllers. Both can be caused by a unit without power, and both are wiring faults once power is proven.

It appeared straight after installation. Is that normal?

It is common, and Vaillant’s cause list explains why: cable diameter, cable type, polarity, separation from mains and earthing of shielded cable are all commissioning details. A new system showing F.9998 should go straight back to the installer as a snag rather than a repair.

Will the heat pump run without the eBUS?

Not usefully. The heat pump takes its demand from the controller over the eBUS, so with the link down it has nothing to respond to. The back-up heater may be called instead depending on how the system was configured, and that shows up on the electricity bill.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?