Ariston 101 fault codewhat it means and how to fix it
The heating circuit has overheated and the appliance has shut down. The usual reason is that water has stopped moving, not that it is firing too hard.
Take care
What 101 means
The leading 1 places this in the central heating group, and 101 is the overheat trip. It is tempting to read an overheat as the burner running too hard, but that is almost never what has happened. In practice the burner is producing heat at its normal rate while circulation has failed, so nothing carries that heat away and the temperature climbs until the safety cut-out operates. Everything worth investigating is therefore on the water side. Ariston group the related faults helpfully: 103 through 107, and the 1P1 to 1P3 warnings, all indicate insufficient circulation, and they frequently appear in the days before a 101. If your appliance has been showing circulation warnings and has now overheated, those were the early stage of the same problem. The reason not to simply keep resetting is that the heat exchanger is the most expensive part of the appliance, and firing it repeatedly without flow is how it gets destroyed.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Pump seized or running weakly | Most often seen on the first cold day of the season after months standing idle. Deposit binds the rotor and it will not turn freely. | Common |
| Air trapped in the primary circuit | An air pocket interrupts flow completely. Radiators cold at the top and knocking or gurgling from the appliance both point here. | Common |
| Sludge restricting the heat exchanger | Magnetite settles in the narrow waterways. Radiators hot at the top and cold across the bottom is the classic indication of a system full of it. | Occasional |
| Valves closed | Every thermostatic valve satisfied at once, a service valve left shut after work, or a motorised zone valve failed closed. | Occasional |
| Overheat thermostat failed | The safety device itself has gone open circuit and is reporting a condition that is not occurring. Confirmed by measurement. | Rare |
What to try yourself
Switch the appliance off and give it half an hour to cool. An overheat trip will not clear while everything is still hot, and you will otherwise think it is dead.
Check the pressure reads 1.0 to 1.5 bar cold. Low pressure and poor circulation are frequent companions.
Open every thermostatic radiator valve fully and confirm the service valves under the appliance are in line with the pipework.
Run the heating twenty minutes and feel each radiator at the top and the bottom. Cold at the top means air you can bleed; cold at the bottom means sludge you cannot.
Reset once. If 101 returns, stop and book an engineer.
Repeated resets fire the burner into an exchanger that is not being cooled. This is exactly how a pump replacement becomes a heat exchanger replacement.
Get a Gas Safe registered engineer to look at your Ariston 101
Gas Safe Register engineers only. No obligation.
What it costs to fix
Typical repair cost
£150–£950
Time on site
40 minutes
A pump is £220 to £420 fitted. A chemical clean with a magnetic filter is £400 to £750. An overheat thermostat by itself is £140 to £220.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Central heating circulating pump
CH-PUMP-15-60£90–£180Plumbing merchant
Price checked 5 August 2026
Magnetic system filter, 22mm
MAG-22£65–£120Plumbing merchant
Price checked 5 August 2026
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Ariston fault codes
- 103Get it checkedThe appliance is reporting insufficient circulation — water is not moving through it fast enough. Worth acting on before it becomes an overheat.Related: overheat and circulation
- E9 219Stop — call an engineerThe boiler has overheated and the safety thermostat has tripped. Water is not carrying heat away from the exchanger, and it should not be run until that is fixed.Related: overheat and circulation
- L1Get it checkedThe boiler is not seeing enough water flow through it to run safely, so it has stopped. Usually a pump, an air lock, or a blocked filter.Related: overheat and circulation
- E02Get it checkedThe overheat thermostat has tripped. Almost always this means water is not moving through the appliance properly rather than that it is running too hot.Related: overheat and circulation
- F.20Stop — call an engineerThe overheat thermostat has tripped because the boiler got too hot. It has shut down to protect itself and it should not be restarted repeatedly.Related: overheat and circulation
- A02Get it checkedThe safety limit thermostat has tripped on overheat. In practice this nearly always means water has stopped circulating properly.Related: overheat and circulation