Ariston 103 fault codewhat it means and how to fix it
The appliance is reporting insufficient circulation — water is not moving through it fast enough. Worth acting on before it becomes an overheat.
Take care
What 103 means
Ariston use a block of codes, 103 through 107, for insufficient circulation, along with the 1P1 to 1P3 warnings for the milder version of the same condition. The appliance works out flow indirectly by watching how quickly the temperature difference between flow and return develops when the burner fires. Water moving properly carries heat away and the two readings stay close together; water barely moving produces a rapid, wide split. When that split exceeds what Ariston consider safe, the appliance reports this group of codes and reduces or stops firing. The valuable thing about seeing 103 rather than 101 is that you have caught the problem at the stage where it is still a circulation fault rather than an overheat. The same causes underlie both, but at this point the heat exchanger has not been repeatedly cooked. Acting now is materially cheaper than acting after two more weeks of resets.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Pump not achieving proper flow | Seized, worn, or set to too low a speed. On modern variable-speed pumps a failing electronic module can also hold the speed down. | Common |
| Air in the system | Frequently follows a refill done too quickly or without running the purge cycle. Air pockets break flow and the appliance sees the temperature split immediately. | Common |
| System heavily sludged | Magnetite narrows the waterways in the heat exchanger and the radiators. Common on systems over ten years old with no inhibitor and no filter. | Occasional |
| Bypass incorrectly set | An automatic bypass valve set wrong, or none fitted where the system needs one, so there is no flow path when the thermostatic valves close. | Occasional |
| Flow or return sensor misreading | The circulation is fine and the measurement is wrong. Worth eliminating, but not where an engineer will begin. | Rare |
What to try yourself
Check the pressure is 1.0 to 1.5 bar cold and top up through the filling loop if not, using the Mode-button purge cycle as Ariston specify.
Open all thermostatic radiator valves fully so the system has somewhere to circulate, and check any service valves below the appliance are open.
Bleed the radiators, working from the ground floor upwards and finishing with the highest one in the property. Top the pressure back up afterwards.
Run the heating for half an hour and note which radiators are cold and whereabouts on the panel. That pattern is the most useful thing you can hand an engineer.
If the code persists after bleeding and repressurising, book an engineer while it is still a circulation fault and not yet an overheat.
Get a Gas Safe registered engineer to look at your Ariston 103
Gas Safe Register engineers only. No obligation.
What it costs to fix
Typical repair cost
£120–£750
Time on site
45 minutes
Bleeding and repressurising costs nothing. A pump is £220 to £420 fitted. A chemical clean with a filter fitted is £400 to £750.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Central heating circulating pump
CH-PUMP-15-60£90–£180Plumbing merchant
Price checked 5 August 2026
Magnetic system filter, 22mm
MAG-22£65–£120Plumbing merchant
Price checked 5 August 2026
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Ariston fault codes
- 101Get it checkedThe heating circuit has overheated and the appliance has shut down. The usual reason is that water has stopped moving, not that it is firing too hard.Related: overheat and circulation
- E9 219Stop — call an engineerThe boiler has overheated and the safety thermostat has tripped. Water is not carrying heat away from the exchanger, and it should not be run until that is fixed.Related: overheat and circulation
- L1Get it checkedThe boiler is not seeing enough water flow through it to run safely, so it has stopped. Usually a pump, an air lock, or a blocked filter.Related: overheat and circulation
- E02Get it checkedThe overheat thermostat has tripped. Almost always this means water is not moving through the appliance properly rather than that it is running too hot.Related: overheat and circulation
- F.20Stop — call an engineerThe overheat thermostat has tripped because the boiler got too hot. It has shut down to protect itself and it should not be restarted repeatedly.Related: overheat and circulation
- A02Get it checkedThe safety limit thermostat has tripped on overheat. In practice this nearly always means water has stopped circulating properly.Related: overheat and circulation