Ariston 109 fault codewhat it means and how to fix it
System pressure has gone above 3 bar. Usually this means somebody overfilled it, or the expansion vessel has failed.
Take care
What 109 means
This is the opposite problem to a 108 and it gets looked up far less often, which is a shame because the underlying cause is frequently more significant. Ariston stop the appliance when heating circuit pressure exceeds 3 bar. Two situations produce that. The straightforward one is overfilling: somebody topped up past the mark, or left a filling loop valve slightly open so the system has been slowly equalising with mains pressure ever since.
The more consequential one is a failed expansion vessel. That vessel exists to absorb the expansion of water as it heats — water expands by roughly four per cent between cold and full operating temperature, and without somewhere for that volume to go the pressure rises steeply every time the heating runs. A system with a dead vessel shows a normal cold reading and a very high hot one, which is the pattern to look for. Left alone it discharges through the safety valve on every cycle, which is why so many overpressure faults eventually present as low pressure instead.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Overfilled during a top-up | Easily done, because the last quarter bar fills much faster than people expect. Harmless and easily corrected. | Common |
| Filling loop left partly open | The system slowly equalises with mains pressure, which is far higher than a heating system should ever see. Check both valves are fully closed. | Common |
| Expansion vessel has lost its charge | The definitive sign is a normal cold pressure that climbs steeply as the system heats. The vessel can often be recharged rather than replaced if the diaphragm is intact. | Occasional |
| Pressure sensor reading high | The sensor is wrong and the pressure is fine. Uncommon, but worth eliminating before anyone replaces a vessel. | Rare |
What to try yourself
Check both filling loop valves are fully closed. If it is a braided hose with lever valves, both levers should sit across the hose, not along it.
Note the pressure cold, then run the heating for half an hour and note it again. A rise of a few tenths of a bar is normal; a rise of a bar or more points firmly at the expansion vessel.
If it is simply overfilled, bleed a small amount out of a radiator into a container until the cold reading comes back to about 1.2 bar. Go slowly — it comes out faster than you expect.
Bleed from a radiator, never from the safety valve. Lifting a safety valve manually often leaves debris on the seat and it then weeps permanently, which turns a five-minute job into a part replacement.If the cold reading is correct but it still climbs past 3 bar when hot, stop and book an engineer to check the expansion vessel charge. That work requires the system to be drained and is not a householder job.
Get a Gas Safe registered engineer to look at your Ariston 109
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£450
Time on site
20 minutes
Free if it is overfilled and you bleed a little out. Recharging an expansion vessel is £90 to £160. Replacing one is £180 to £450 depending on whether it is internal or external.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Expansion vessel (8 litre, sealed system)
EV-8L£35–£85Plumbing merchant
Price checked 28 September 2026
Pressure relief valve, 3 bar
PRV-3B£18–£42Plumbing merchant
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Ariston fault codes
- 108Usually simple to fixThe heating circuit does not contain enough water to run safely. Refill through the filling loop to about 1.2 bar and the code clears.Related: water pressure
- 501Get it checkedNo flame was detected during ignition and the appliance has locked out. Check the gas supply and the condensate pipe before booking anyone.Related: same brand
- 101Get it checkedThe heating circuit has overheated and the appliance has shut down. The usual reason is that water has stopped moving, not that it is firing too hard.Related: same brand
- 103Get it checkedThe appliance is reporting insufficient circulation — water is not moving through it fast enough. Worth acting on before it becomes an overheat.Related: same brand
- 604Get it checkedFan speed is outside the range the appliance expects, so it will not allow the burner to light. This one needs an engineer.Related: same brand
- 303Get it checkedThe main control board has reported an internal fault. It needs an engineer, and it is worth checking the electrical supply before assuming the board is dead.Related: same brand
Own an Ariston boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.