System pressure has gone above 3 bar. Usually this means somebody overfilled it, or the expansion vessel has failed.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ariston properly.

What 109 means

This is the opposite problem to a 108 and it gets looked up far less often, which is a shame because the underlying cause is frequently more significant. Ariston stop the appliance when heating circuit pressure exceeds 3 bar. Two situations produce that. The straightforward one is overfilling: somebody topped up past the mark, or left a filling loop valve slightly open so the system has been slowly equalising with mains pressure ever since. The more consequential one is a failed expansion vessel. That vessel exists to absorb the expansion of water as it heats — water expands by roughly four per cent between cold and full operating temperature, and without somewhere for that volume to go the pressure rises steeply every time the heating runs. A system with a dead vessel shows a normal cold reading and a very high hot one, which is the pattern to look for. Left alone it discharges through the safety valve on every cycle, which is why so many overpressure faults eventually present as low pressure instead.

What causes it

Causes of the Ariston 109 fault code, most common first
CauseWhat is actually happeningHow likely
Overfilled during a top-upEasily done, because the last quarter bar fills much faster than people expect. Harmless and easily corrected.Common
Filling loop left partly openThe system slowly equalises with mains pressure, which is far higher than a heating system should ever see. Check both valves are fully closed.Common
Expansion vessel has lost its chargeThe definitive sign is a normal cold pressure that climbs steeply as the system heats. The vessel can often be recharged rather than replaced if the diaphragm is intact.Occasional
Pressure sensor reading highThe sensor is wrong and the pressure is fine. Uncommon, but worth eliminating before anyone replaces a vessel.Rare

What to try yourself

  1. Check both filling loop valves are fully closed. If it is a braided hose with lever valves, both levers should sit across the hose, not along it.

  2. Note the pressure cold, then run the heating for half an hour and note it again. A rise of a few tenths of a bar is normal; a rise of a bar or more points firmly at the expansion vessel.

  3. If it is simply overfilled, bleed a small amount out of a radiator into a container until the cold reading comes back to about 1.2 bar. Go slowly — it comes out faster than you expect.

    Bleed from a radiator, never from the safety valve. Lifting a safety valve manually often leaves debris on the seat and it then weeps permanently, which turns a five-minute job into a part replacement.
  4. If the cold reading is correct but it still climbs past 3 bar when hot, stop and book an engineer to check the expansion vessel charge. That work requires the system to be drained and is not a householder job.

Get a Gas Safe registered engineer to look at your Ariston 109

Gas Safe Register engineers only. No obligation.

What it costs to fix

Typical repair cost

£0–£450

Time on site

20 minutes

Free if it is overfilled and you bleed a little out. Recharging an expansion vessel is £90 to £160. Replacing one is £180 to £450 depending on whether it is internal or external.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 5 August 2026

Pressure relief valve, 3 bar

PRV-3B£18–£42Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.