Ariston 501 fault codewhat it means and how to fix it
No flame was detected during ignition and the appliance has locked out. Check the gas supply and the condensate pipe before booking anyone.
Take care
What 501 means
The 5 at the front tells you this is the ignition and detection group, and 501 is the lockout that follows repeated failed attempts to establish a flame. Ariston distinguish this from the warnings that precede it: 5P1 and 5P2 record a first and second failed ignition attempt while the appliance is still trying, and 5P6 is a general ignition-failed warning. By the time you see 501 the appliance has given up. Ariston describe this as a non-volatile shutdown, meaning it will not clear itself and needs a manual reset. What the code cannot tell you is why the flame never appeared. Four causes account for almost all of them, and helpfully the two most common are things you can investigate yourself: no gas actually reaching the appliance, and a condensate drain frozen solid outside. The other two, a worn ignition electrode and a gas valve fault, need an engineer.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Frozen condensate pipe | The plastic drain outside ices up and condensate backs into the appliance within a minute of firing. Dominates this fault in cold weather. | Common |
| Gas supply interrupted | Prepayment meter out of credit, the emergency control valve knocked shut, or a genuine supply problem. Test it by trying a gas hob. | Common |
| Ignition electrode worn | A consumable part. The tip erodes over years until the spark is too weak to light the burner dependably. | Occasional |
| Gas valve fault | Not opening, or not delivering a stable enough rate to establish a flame. The dearest possibility and the rarest. | Rare |
What to try yourself
Light a gas hob ring. If it will not light either, the gas supply is the problem and the boiler is doing exactly what it should.
If you are on a prepayment meter, check the credit including any emergency credit that may have run out overnight.
Outside, trace the white or grey plastic condensate pipe down from the appliance and feel along it for a solid, ice-cold length — the bends and the open end freeze first.
Thaw any ice with hand-hot water poured slowly along the pipe. Boil a kettle and let it stand ten minutes so it is hot but not scalding.
Never use boiling water, a heat gun, or any naked flame. Cracking a cold plastic pipe turns a free repair into a plumbing job in the worst possible weather.Press reset once. If the appliance lights and holds, the condensate was the cause — get the external run lagged before next winter.
Get a Gas Safe registered engineer to look at your Ariston 501
Gas Safe Register engineers only. No obligation.
What it costs to fix
Typical repair cost
£0–£320
Time on site
25 minutes
Nothing if it is a frozen condensate pipe you clear yourself. An ignition electrode is £110 to £190 fitted; a gas valve £240 to £320.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Condensate trap and siphon
COND-TRAP£15–£38Plumbing merchant
Price checked 5 August 2026
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Ariston fault codes
- 303Get it checkedThe main control board has reported an internal fault. It needs an engineer, and it is worth checking the electrical supply before assuming the board is dead.Related: ignition and gas supply
- EA 227Stop — call an engineerThe boiler tried to light and never detected a flame, so it has shut the gas off and locked out. This is the most common Worcester fault code.Related: ignition and gas supply
- E01Get it checkedThe appliance tried to light and could not confirm a flame, so it has locked out. In winter a frozen condensate pipe is the most likely reason.Related: ignition and gas supply
- F.28Stop — call an engineerThe boiler tried to light and failed three times in a row, so it has shut the gas off and locked out. Do not keep resetting it.Related: ignition and gas supply
- A01Get it checkedThe burner failed to light and the appliance has locked out. Check the gas supply and, in cold weather, the condensate pipe before calling anyone.Related: ignition and gas supply
- L2Stop — call an engineerThe boiler failed to detect a flame during ignition and has locked out on the gas valve. Do not keep resetting it.Related: ignition and gas supply
Related guides
Common questions about Ariston 501
What is the difference between 501 and 5P1?
5P1 is a warning logged after a single failed ignition attempt while the appliance is still trying. 501 is the lockout it reaches after repeated failures. Seeing 5P1 in the error list after the appliance recovered is normal history; seeing 501 on the display means it has stopped.
The display says I have used all my resets. What now?
Ariston allow five resets in fifteen minutes and then require a full power cycle at the fused spur. Switch it off, leave it a minute, switch it back on. But treat that as a signal to stop resetting and book an engineer rather than as a way to get more attempts.
Could a blocked flue cause this?
Yes. A blocked or badly positioned flue terminal prevents clean combustion and produces the same lockout. Have a look at the terminal from outside while you are checking the condensate pipe — nests and render splashes are both common.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
- Trade body guidance
Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.