Ariston 604 fault codewhat it means and how to fix it

Get it checkedBoilerClas HE Evo and Clas HE System Evo; the One series uses 612Last updated

Fan speed is outside the range the appliance expects, so it will not allow the burner to light. This one needs an engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ariston properly.

Get a Gas Safe registered engineer to look at your Ariston 604

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What 604 means

The leading 6 marks this as the air inlet and flue gas outlet group, and Ariston's description of 604 is "insufficient fan speed". The appliance commands a speed, reads the feedback from the fan, and refuses to open the gas valve unless the two agree — the fan is what removes combustion products through the flue, and firing without proven extraction is not something any manufacturer permits. Which number you see depends on the generation, and it is worth being clear about because the lists on the open web are not.

604 is the Clas HE Evo's code. On the current One series the same fault is 612, described as insufficient fan speed on the Clas One and as a fan error with the speed higher or lower than the set values on the Genus One+. The renumbering matters more than it sounds, because 610 moved too: on the Evo it is a thermofuse, on the One it is an overheat of the main heat exchanger.

Two things realistically cause the fan fault. The first is a worn fan: bearings dry out after eight to twelve years and the fan slows or stops, usually after months of grumbling on start-up that the household stops registering. The second is a flue obstruction, which alters the resistance the fan works against and throws the speed reading even though the fan is fine. Checking the flue before condemning the fan is the difference between a call-out charge and a four-hundred-pound part.

What causes it

Causes of the Ariston 604 fault code, most common first
CauseWhat is actually happeningHow likely
Fan bearings worn outThe leading cause on appliances past eight years or so. Listen back for whether there has been increasing noise on start-up over recent months.Common
Flue terminal obstructedBird nest, leaf debris, or render pushed into the terminal during building work. Enough to change fan loading and fail the check.Occasional
Fan wiring or connector faultThe fan spins but the tachometer signal never arrives at the board. Inexpensive if that is all it is.Occasional
Control board faultThe board misreads a healthy signal. Only concluded after the fan and flue have been properly eliminated.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£180–£420

A replacement fan is typically £280 to £420 fitted. If it turns out to be a flue obstruction or a connector, expect a call-out charge of £80 to £140.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?