This fault can involve incomplete combustion and carbon monoxide.
If anyone in the property feels sick, dizzy or drowsy, or you can smell gas: open the windows, leave the building, and do not switch anything on or off. Then call the National Gas Emergency Service.
0800 111 999Baxi E.04.10 fault codewhat it means and how to fix it
Ignition failure on the Baxi 200/400 Combi and every Combi 2: the burner would not light after its allowed attempts. Baxi's own quick guide names it the frozen-condensate code you can fix yourself.
Take care
Get a Gas Safe registered engineer to look at your Baxi E.04.10
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What E.04.10 means
E.04.10 is the ignition lockout on the two newest Baxi display systems, and the two manuals define it slightly differently. The 2016 Baxi 200 and 400 Combi manual, where it is shown as E04 alternating with 10, calls it "5 burner start-up failures"; the 600 Combi 2 manual of 2023, where it is printed with dots, says "Burner failed to ignite after 4 attempts", and Baxi's professional page uses the Combi 2 wording. Either way the board has sparked, seen no flame, and stopped with a permanent fault — the letter E — that "prevents the boiler operating and will not automatically reset".
The reset differs by generation and both are quoted here because the hold times are not the same: on the 200 and 400 Combi "the RESET button must be pressed for at least 3 seconds to restart the boiler", and the same manual warns that "pressing the RESET button for 5 seconds will start the de-aeration process", a five-minute purge you did not ask for; on the Combi 2 "press the RESET button for one second".
Baxi's quick-start guide for the Combi 2 puts E.04.10 in a box headed "Error codes that you can put right yourself" with the explanation "Frozen condensate pipe — sometimes when it's very cold, the white plastic condensate pipe outside freezes, and your boiler will shut down to protect itself", and points to their thawing video. That is the householder's share of this code. The installer's share, from the Combi 2 table, is longer: gas supply pressure, gas valve connection and calibration, electrode connections and condition, fan operation and "the condition of the flue gas exhaust (blockages)"; the 200/400 table adds "check the earthing" and, for a spark with no flame, "purge the gas supply to remove air". A related code, H.03.02 "temporary flame loss", is the same boiler losing a flame it had lit and trying again on its own, and E.01.04 is that happening five times in a day.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Frozen condensate pipe | The cause Baxi name for the householder. Ice in the outside run of the white plastic pipe blocks the drain, condensate backs up, and the burner cannot light. Thaw it and reset. | Common |
| Gas supply | The first item in both engineer tables: "check the gas supply pressure", "check that the gas valve is fully opened", and after a meter change or long shutdown "purge the gas supply to remove air". A prepayment meter with no credit produces the same code. | Common |
| Ignition electrode or its wiring | Both manuals: check the electrode connections and condition, and on the 200/400 "replace the ionization/ignition electrode" and "check the earthing". A cracked or eroded electrode sparks weakly or senses no flame. | Common |
| Gas valve or its calibration | The Combi 2 table: "check the gas valve electrical connection, check the gas valve calibration, check the operation of the gas valve". Set with an analyser; an engineer-only adjustment on a sealed component. | Occasional |
| Fan or flue | Last in the Combi 2 list: "check the operation of the fan" and "the condition of the flue gas exhaust (blockages)". The 200/400 adds "check that there is no recirculation of flue gases". A boiler that cannot move its combustion air will not light. | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£0–£450
Time on site
45 minutes
Thawing the pipe or restoring gas costs nothing. Electrode fitted £110–£180. Gas valve calibration within a service visit; replacement £280–£450. Fan £200–£320.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Condensate trap and siphon
COND-TRAP£15–£38Plumbing merchant
Price checked 28 September 2026
Baxi / Potterton / Main detection and spark ignition electrode
7686344£25–£60Authorised Baxi parts distributor
Price checked 28 September 2026
Baxi / Potterton / Main gas valve
7683968£120–£240Authorised Baxi parts distributor
Price checked 28 September 2026
Baxi / Potterton / Main fan assembly
7683926£110–£220Authorised Baxi parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Baxi fault codes
- E133Get it checkedBaxi's ignition lockout: "the gas supply has been interrupted, ignition has failed or the flame has not been detected". Check the gas is on, reset once. If it returns, stop.Related: ignition and gas supply
- E128Get it checkedFlame failure while the burner was running, on the digital-display Baxis. The boiler relights itself unless it keeps happening; Baxi's manuals name gas supply, electrode and flue as the things to check.Related: ignition and gas supply
- E134Get it checkedBaxi's "elapsed time — gas valve open without gas": the valve opened, nothing arrived. Check the meter and credit before anything else; it resets from the panel.Related: ignition and gas supply
- E.01.04Stop — call an engineer"Flame loss detected five times in 24 hours": the burner keeps lighting and going out on a Baxi 200/400 Combi or Combi 2. Gas pressure, valve calibration, flue or electrode — an engineer's list.Related: ignition and gas supply
- E09Get it checkedGas valve connection cable fault on the 600, 800, Compact and Duo-tec 2. The board cannot talk to the valve. Baxi allow one reset; a repeat means the wiring or the PCB.Related: ignition and gas supply
- E135Get it checkedBaxi's "interruption of gas supply (internal error)". Same family as E133 and E134 but the manual calls it internal, so a reset that fails means the board or gas valve circuit.Related: ignition and gas supply
Own a Baxi boiler? Save it and its codes come first next time.
Related guides
Common questions about Baxi E.04.10
Why does the manual say four attempts and the older one five?
Because the two ranges count differently. The 2016 Baxi 200/400 Combi manual defines E04 10 as "5 burner start-up failures"; the 2023 Combi 2 manual defines E.04.10 as "burner failed to ignite after 4 attempts". Same lockout, different threshold.
Is E04 10 the same as E.04.10?
Yes. The 200 and 400 Combi show the code as two alternating pairs, E04 then 10; the Combi 2 prints it with dots on a larger display. Baxi describe both as a permanent fault that needs the RESET button.
What is the difference between E.04.10 and H.03.02?
H.03.02 is "temporary flame loss": the burner lit, lost its flame, and the boiler will retry on its own. E.04.10 is the boiler giving up after its allowed ignition attempts and waiting for a reset.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.