Baxi E133 fault codewhat it means and how to fix it

Stop — call an engineerBoilerDuo-tec and 600 seriesLast reviewed

The boiler failed to establish a flame and has locked out on the gas valve. Do not reset it more than twice.

Get a Gas Safe registered engineer to look at your Baxi E133

Gas Safe Register engineers only. No obligation.

What is the weather doing, and what else uses gas?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

It is below freezing and the boiler worked yesterday

A frozen condensate pipe is the overwhelming favourite. It is the single most common winter Baxi call-out.

Pour warm water along the external white plastic pipe — never boiling, which can crack it — and reset once.

Other gas appliances are not working either

No gas at the property. The boiler is behaving correctly.

Check the meter valve and any prepayment credit, then call your supplier.

Gas is fine everywhere else and it is not cold

The fault is inside the boiler — most likely the electrode, possibly the gas valve.

Book a Gas Safe registered engineer and stop resetting.

You can smell gas

Stop. Do not reset, do not touch light switches.

Leave the property, open windows on the way out, and call 0800 111 999.

What E133 means

E133 is a gas supply or ignition failure lockout. The boiler ran its ignition sequence and did not confirm a flame, so it shut the gas valve and latched the fault rather than trying indefinitely. That behaviour is deliberate: an appliance that keeps attempting ignition keeps putting unburnt gas into a combustion chamber. In practice the causes fall into three groups — no gas arriving at the appliance, an ignition or flame sensing electrode that has degraded, or a condensate pipe blocked with ice. The last is seasonal and by far the easiest for a householder to check.

What causes it

Causes of the Baxi E133 fault code, most common first
CauseWhat is actually happeningHow likely
No gas at the applianceEmpty prepayment meter, closed service valve, or a supply interruption.Common
Frozen condensate pipeBaxi condensate runs are often long and horizontal. The first hard frost ices them up and the boiler cannot complete a cycle.Common
Ignition or flame sensing electrode degradedCarbon build-up stops the electrode detecting the flame it has lit.Common
Gas valve faultNot opening, or opening too slowly for the ignition window.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£450

Time on site

1 hour

Thawing a condensate pipe is free. Insulating and re-routing it £120–£250. Electrode £130–£220. Gas valve £280–£450.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Ideal Logic ignition electrode

175565£18–£42Authorised Ideal parts distributor

Price checked 5 August 2026

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Common questions about Baxi E133

How do I thaw a frozen condensate pipe safely?

Use warm water from a kettle that has been left to stand, or a hot water bottle held against the pipe. Never use boiling water — the thermal shock can crack the plastic and turn a free fix into a plumbing job. Pour along the length of the pipe, not just at one point.

Why does the condensate pipe keep freezing?

Because it is too small, too long, or has too little fall. The permanent fix is to increase the pipe diameter outside, insulate it, and reduce the horizontal run. That costs £120 to £250 and stops it happening every winter.

How many resets are safe?

Two. Each reset starts a new set of ignition attempts, and each attempt releases a little gas before the valve shuts. If two have not worked, the fault is real.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Trade body guidance
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process