Baxi E128 fault codewhat it means and how to fix it

Get it checkedBoilerDigital display with an R symbol: Baxi 600 and 800 Combi and System, Duo-tec 2 Combi GA, Duo-tec, Platinum and Megaflo Compact, Megaflo System, Assure, EcoBlue Advance and Plus. Not printed in the selector-switch Duo-tec HE or Platinum tables, which only have E133.Last updated

Flame failure while the burner was running, on the digital-display Baxis. The boiler relights itself unless it keeps happening; Baxi's manuals name gas supply, electrode and flue as the things to check.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

Get a Gas Safe registered engineer to look at your Baxi E128

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

When does the flame go out?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

Only in freezing weather

Condensate is backing up because the outside pipe is partly iced. The flame dies when water reaches the combustion side.

Thaw the external pipe with warm water and reset once. Have the pipe insulated or re-routed if it recurs.

When a tap is running or the boiler is at full output

Gas pressure or the valve setting cannot hold the flame at high fire. Both are engineer checks with a manometer and analyser.

Book a service and mention when it happens.

At random, in any weather

Electrode or flue. Neither is visible from outside the case.

Engineer visit; ask for the electrode and the flue seals to be checked.

What E128 means

E128 is printed only on Baxi's digital-display generation — the Duo-tec 2, the Compact ranges, the 600 and 800, Assure, Megaflo System and EcoBlue — and the 600 and 800 manuals define it in one sentence: "128 is displayed if there has been a flame failure during normal operation." That distinguishes it from E133, which is a failure to light in the first place.

With E128 the burner was alight and the flame signal went. The EcoBlue Advance user guide labels the same number "Flame Failure (no lock-out)", which is the useful clue: on its own E128 is a report, and the boiler retries. It is also one of the codes the 600 and 800 manuals say can be relit from the panel: "By pressing the Reset button for 1 to 3 seconds when 09, 15, 110, 125, 128, 133, 134, 135, 384 are displayed it is possible to relight the boiler." Baxi's professional table adds two neighbours you may see instead. E129 is "Safety error for frequent loss of flame with max correction during ignition during Calibration Function" — the same problem caught while the board was calibrating the gas valve — and the EcoBlue Advance prints E151 as a straightforward "Flame Failure" alongside E128.

A flame that lights and then dies points at whatever is disturbing it: gas pressure sagging when other appliances run, a flue that is letting exhaust back to the air inlet, a condensate trap or pipe partly blocked so that water backs up into the combustion side, or a sensing electrode that is losing the signal as it heats. The 600 Combi fault-finding flow for a burner that "does not stay alight" checks the gas valve setting (CO2), then the sensing electrode and its lead and position, then the board.

What causes it

Causes of the Baxi E128 fault code, most common first
CauseWhat is actually happeningHow likely
Condensate backing upA partly frozen pipe or a trap full of debris lets water rise into the burner space and snuff the flame mid-cycle. It clears, the boiler relights, and it happens again an hour later. Baxi's 600 user guide lists "condensate drain blocked" among the things to check when the boiler stops.Common
Flame-sensing electrode losing the signalThe electrode reads the flame through a small current. As it wears or coats with deposit the signal weakens, and the board decides the flame has gone while it is still burning. Baxi's flow checks the sensing electrode, its lead and its position.Common
Gas pressure dropping under loadThe 600 and 800 manuals want 19 mbar minimum at the meter. An undersized supply or a partly closed cock can hold a flame at low fire and lose it as the burner ramps up.Occasional
Flue recirculationA flue terminal in a sheltered corner, a damaged seal or a joint that has moved can feed exhaust back to the air inlet. The flame lights on clean air and dies as the recirculated gas builds.Occasional
Gas valve setting driftedBaxi's first check for a burner that goes out is the set of the gas valve against the CO2 values in the manual. It is a combustion-analyser adjustment, not a screwdriver one.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£350

Time on site

45 minutes

Free if thawing the condensate pipe clears it. Electrode (Baxi 7686344) fitted £110–£180. Flue seal or terminal work £120–£250. Gas valve adjustment is part of a service; replacement £280–£450.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 28 September 2026

Baxi / Potterton / Main detection and spark ignition electrode

7686344£25–£60Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi / Potterton / Main gas valve

7683968£120–£240Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Baxi boiler? Save it and its codes come first next time.

Common questions about Baxi E128

Can I reset E128 myself?

Yes. It is in Baxi's list of codes that can be relit with the Reset button held for one to three seconds (two seconds on the EcoBlue Advance). If it comes back the same day, the cause needs finding rather than clearing.

What is the difference between E128 and E133?

E133 is a failure to light: three attempts, no flame, lockout. E128 is a flame that was burning and went out during normal operation. Baxi define both in the 600 and 800 manuals and they point at different things — supply and ignition for E133, flame stability for E128.

What are E129 and E151?

E129 is on Baxi's professional table as repeated flame loss caught during the gas valve calibration function; treat it as E128 with the calibration to be redone. E151 is printed only on the EcoBlue Advance as "Flame Failure", where E128 is the no-lockout version of the same event.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?