Glow-worm F.20 fault codewhat it means and how to fix it
The safety thermal cut-out has tripped and stopped the boiler. Glow-worm's homeowner page lets you check pressure, radiator valves and airlocks first; on Ultracom2 boilers F20 trips at 97 °C.
Take care
What did you find?
The right answer depends on what you can see. Pick the one that matches.
Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.
Pressure was low or a radiator was full of air
Correct it, reset once, and see whether it stays away. Glow-worm list both as causes.
Pressure fine, but valves were closed or a zone valve is not moving
Open what you can. A zone valve or external pump that is not working wants an installer.
Installer visit; this is a system fault rather than a boiler fault.
Everything looks right and F.20 keeps returning
Pump, sensor or a blockage inside the boiler.
Book a Gas Safe registered engineer and stop resetting.
What F.20 means
On the current ranges Glow-worm print F.20 as "Safety shutdown: Overheating temperature reached", and the Compact manual calls it the "temperature cut-out safety shutdown". The water in the heat exchanger got hotter than the board will tolerate, and rather than let it boil the boiler stopped.
The installation manuals list the electrical explanations — an incorrect earth connection between the harness and the appliance, a flow or return sensor loose or defective, a stray spark from the ignition cable, plug or electrode upsetting the reading — but Glow-worm's homeowner fault-code page is where the everyday causes are: "system water pressure below normal range of 1 to 1.5 bar", "circulation fault, pump, valve, blockage", and airlocks. It is also the page that tells you what you may do: "check the water pressure and refill the system if needed. Look for leaks... Ensure radiator valves are open, and external pumps and zone valves are working correctly. Make sure there are no airlocks in the system", and then to treat it as a case for an installer in the first instance because it "can relate to how the boiler is working with the heating system".
On the two-digit Ultracom2, Betacom 24a and Betacom2 the same F20 is "overheating fault — overheating safety device activated (97 °C)", with the pump, the harness and closed flow and return isolation valves as the checks. On the Ultracom, Flexicom and Ultrapower the overheat is F5 and their guides say "allow to cool then press reset button", and on those boilers a 20 means something else entirely — software incompatibility on the cxi, an incompatible user interface on the CI range.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Not enough water moving through the heat exchanger | Radiator valves closed, a zone valve stuck, a pump slowing with age or a blockage in the flow — Glow-worm's "circulation fault, pump, valve, blockage". The burner keeps heating the same water and the cut-out catches it. | Common |
| System pressure low or air trapped | First on the homeowner page's list. Low pressure and airlocks both leave pockets where water is not carrying heat away, and the sensor at that point sees a spike. | Common |
| Flow or return sensor loose or failing | A sensor that has slipped off its pipe or is reading wrongly can report an overheat that never happened. Glow-worm list "flow or return NTC defective (loose connection)" against F.20 on every current range. | Occasional |
| Earthing or ignition interference | The installation manual's odd-looking causes — a poor product earth or a stray spark via the ignition cable — corrupt the sensor signal for an instant and the board reads it as a temperature jump. | Rare |
What to try yourself
Let the boiler cool for twenty minutes before anything else. On an Ultracom, Flexicom or Ultrapower showing F5, Glow-worm's guides make this the first instruction.
Check the pressure and, if it is below the 1.0 to 1.5 bar the homeowner page names, top up as the F.22 page describes. Look for any sign of a leak while you are there.
Walk round the radiators: are the valves open, including any thermostatic heads turned to frost? If you have zone valves or an external pump, are they moving and running when the heating calls? Bleed any radiator that is cold at the top.
Reset once as your guide describes. If F.20 returns, Glow-worm say this is a case for your installer in the first instance — leave it off and book the visit rather than repeating the cycle.
Do not touch the pipework under the boiler while the code is showing; the flow pipe can be very hot for some minutes after a cut-out.
Get a Gas Safe registered engineer to look at your Glow-worm F.20
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£420
Time on site
40 minutes
Free if it was pressure, air or a closed valve. Sensor £90–£160. Pump £250–£420. Zone valve or external pump repair by an installer £120–£300.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Central heating circulating pump
CH-PUMP-15-60£90–£180Plumbing merchant
Price checked 28 September 2026
Magnetic system filter, 22mm
MAG-22£65–£120Plumbing merchant
Price checked 28 September 2026
Glow-worm flow or return temperature sensor (clip-on NTC)
£12–£35Authorised Glow-worm parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Glow-worm fault codes
- F.83Get it checkedThe burner lit but neither sensor registered any warming — Glow-worm call it dry fire. Low pressure or a sensor off its pipe; the Energy7 guide allows two resets before a 45-minute lockout.Related: overheat and circulation
- F.24Get it checkedThe temperature at the sensor climbed faster than water flowing properly would allow. Glow-worm list the pump, air, low pressure and a stuck non-return valve, and send it to an engineer.Related: overheat and circulation
- F.23Get it checkedThe flow and return temperatures are too far apart, which means water is barely moving through the boiler. Glow-worm point at the pump, air, or the two sensors swapped over.Related: overheat and circulation
- F.76Stop — call an engineerThe thermal fuse on the primary heat exchanger has operated or failed. It exists to catch a dry fire the sensors missed, and Glow-worm's test for it is not one an owner performs.Related: overheat and circulation
- F.86Get it checkedThe external safety contact — usually an underfloor heating limit thermostat wired to the boiler — is open, or its link is missing. The boiler will not fire until the contact closes.Related: overheat and circulation
- F.28Get it checkedThree ignition attempts have failed and the boiler has locked out. Glow-worm's guides let you check the gas supply and the condensate pipe and reset three times before calling anyone.Related: same brand
Own a Glow-worm boiler? Save it and its codes come first next time.
Related guides
Common questions about Glow-worm F.20
Is F.20 dangerous?
It is the protection working. The reason not to reset repeatedly is that each cycle boils the same trapped water and stresses the heat exchanger; the cut-out is not a substitute for finding the cause.
My Flexicom shows F5, not F20. Same fault?
Yes. The Ultracom, Flexicom and Ultrapower list uses F5 for the overheat and their guides say allow it to cool, then press reset. Their F20 is a software code that has nothing to do with heat.
What does 97 °C mean on the Betacom2?
It is the point at which the overheating safety device on the Ultracom2, Betacom 24a and Betacom2 trips, printed in their installation manuals. The current ranges do not publish the figure.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.