Glow-worm F.76 fault codewhat it means and how to fix it

Stop — call an engineerBoilerF.76 on Energy7 and Compact · F76 on Ultracom2 and Betacom 24a/28a · not printed for Ultimate3, Easicom3, Betacom3/4, Ultracom, Flexicom or UltrapowerLast updated

The thermal fuse on the primary heat exchanger has operated or failed. It exists to catch a dry fire the sensors missed, and Glow-worm's test for it is not one an owner performs.

Get a Gas Safe registered engineer to look at your Glow-worm F.76

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.76 means

F.76 is a code most Glow-worm manuals do not print, and the ones that do describe a last-line safety device. The Energy7 manual calls it "the safety cut-out in the primary heat exchanger is defective — safety cut-out feedback does not match the gas valve assembly feedback"; the Compact manual, "Fault: Thermal cut-out — defective thermal fuse"; and the Betacom 24a manual, which uses the two-digit F76, "thermal fuse fault — thermal fuse disconnected, defective thermal fuse", adding in its commissioning section that the fuse "protects the appliance against dry fire". It is a one-shot device fixed to the heat exchanger body.

If the metal reaches a temperature the flow sensor should have stopped long before, the fuse opens, the gas valve loses its permission, and the boiler shows F.76 for good — a blown fuse cannot be reset. The Compact manual's procedure for the engineer explains why this page is danger rather than caution: "check the heat exchanger for leakages. If the heat exchanger has no leaks, bypass the thermal fuse. If you can then start the product, replace the thermal fuse."

Bypassing a safety fuse to test a boiler is a competent person's diagnostic step under controlled conditions and nothing else; the Betacom 24a manual's remedy is blunter still, "replace the heat exchanger", because on that boiler the fuse is part of it. A fuse that has genuinely operated means the heat exchanger has already been much too hot once, and the reason — no water, a dead pump, a sensor off its pipe — has to be found before the boiler runs again. The Ultimate3, Easicom3, Betacom3 and Betacom4 tables do not list F.76, and the Ultracom, Flexicom and Ultrapower lists have no 76 at all.

What causes it

Causes of the Glow-worm F.76 fault code, most common first
CauseWhat is actually happeningHow likely
Heat exchanger overheated and the fuse openedThe fuse did its job. Something let the exchanger run dry or stagnant — low pressure, a stuck pump, a sensor reading the wrong pipe — and the sensors did not catch it first. That cause has to be found as well as the fuse.Common
Fuse or its plug disconnectedThe Betacom 24a manual's "thermal fuse disconnected" and its instruction to check the fuse's connections. A plug left off after a heat exchanger clean produces F.76 with nothing overheated.Occasional
Heat exchanger leakingThe first thing the Compact manual tells the engineer to check. A weeping exchanger can wet the fuse or its wiring, and a fuse replaced on a leaking exchanger will go again.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£150–£800

Time on site

2 hours

Thermal fuse and cause £150–£350. Heat exchanger £450–£800.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Glow-worm flow or return temperature sensor (clip-on NTC)

£12–£35Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.76

Can it be reset?

No. A thermal fuse that has operated is open circuit for good, and the board will show F.76 until it is replaced. Pressing reset repeatedly changes nothing.

Why danger, when the boiler is stopped?

Because the diagnostic Glow-worm print involves bypassing a safety device, and because a fuse that has blown means the heat exchanger has already been overheated once. Neither is territory for anyone but a Gas Safe registered engineer.

What will it cost?

A fuse and the fault behind it, £150–£350. If the heat exchanger has to be replaced, as the Betacom 24a manual requires, £450–£800 — at which point on an older boiler the conversation may turn to replacement.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this