Glow-worm F.86 fault codewhat it means and how to fix it

Get it checkedBoilerF.86 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F86 on Ultracom2, Betacom 24a/28a and Betacom2Last updated

The external safety contact — usually an underfloor heating limit thermostat wired to the boiler — is open, or its link is missing. The boiler will not fire until the contact closes.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.86

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.86 means

On the Energy7, Ultimate3, Easicom3, Betacom3 and Betacom4, Glow-worm print F.86 as "Fault: Underfloor heating contact — underfloor heating contact open, sensor disconnected or defective". The Compact manual generalises it to "external safety shutdown" and lists what might be behind it: limit thermostat settings incorrect, the flow sensor reading deviating values, a blocked three-port diverter valve, a defective condensate pump. The idea is the same on every range. The board has a pair of terminals for an external safety device — in a UK house almost always the high-limit stat on an underfloor heating manifold, sometimes a condensate pump's alarm contact — and it will not run while that circuit is open.

On a boiler without any such device the terminals carry a factory link, and F.86 on one of those means the link has been removed or has fallen out, which is exactly what the Ultracom2, Betacom 24a and Betacom2 manuals say for their two-digit F86: "check that the sensor is connected to the main board and the shunt is removed" when a sensor is fitted, and by implication that the shunt is present when it is not.

So F.86 divides neatly. If you have underfloor heating, the floor got too hot or its stat tripped, and the boiler is protecting your floor; let it cool and see whether the code clears. If you have no underfloor heating and no condensate pump, a wire has come adrift inside the casing, and that is an engineer's five minutes. Glow-worm's user guides give the householder nothing for F.86 on any range.

What causes it

Causes of the Glow-worm F.86 fault code, most common first
CauseWhat is actually happeningHow likely
Underfloor limit thermostat trippedThe stat on the manifold opens when the floor circuit gets too hot — a mixing valve failed, a pump on the manifold stopped, or the stat is set too low. Glow-worm's "underfloor heating contact open".Common
Factory link removed or fallen outOn a boiler with no external safety device the terminals must be bridged. The two-digit manuals talk about the shunt; a link disturbed during installation or a controls change leaves the circuit open.Common
Sensor or wiring defectiveGlow-worm's "sensor disconnected or defective". A broken wire to the manifold, or a stat that has failed open, reads as a permanent trip.Occasional
Condensate pump alarm — CompactThe Compact manual lists a defective condensate pump against F.86, because a pump's alarm contact can be wired to the same terminals. If your boiler drains through a pump, its float or its wiring is a candidate.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£300

Time on site

45 minutes

Link or wire refitted £80–£130. Limit stat £60–£120. Manifold valve or pump £150–£300.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.86

I have no underfloor heating. Why am I seeing this?

Then the terminals should be bridged and are not — a link out, or a wire off. Glow-worm's two-digit manuals talk about the shunt for exactly this reason. It is a quick job, but it is inside the casing.

I do have underfloor heating. Can I wait for it to cool?

Yes. If the manifold's limit stat has tripped, the code clears when the floor circuit cools and the stat closes. If it trips again, the manifold mixing valve or pump wants attention from whoever fitted the floor.

Cost?

A link refitted or a wire reconnected, a call-out fee of £80–£130. A limit stat £60–£120. A manifold mixing valve or pump, £150–£300, from a heating installer rather than a boiler engineer.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?