Glow-worm F.23 fault codewhat it means and how to fix it
The flow and return temperatures are too far apart, which means water is barely moving through the boiler. Glow-worm point at the pump, air, or the two sensors swapped over.
Take care
Get a Gas Safe registered engineer to look at your Glow-worm F.23
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What F.23 means
F.23 is "Safety shutdown: Temperature spread too great (NTC1/NTC2)" in Glow-worm's tables, and the two-digit Ultracom2 and Betacom2 manuals say the same thing in plainer English: "maximum temperature difference reached between return and flow heating — water circulation fault". The flow sensor sits where hot water leaves the heat exchanger and the return sensor where cooler water comes back; the difference between them is a measure of how fast water is moving, and when it opens beyond the board's limit the boiler concludes the water is standing still.
Glow-worm's causes on the current ranges are "pump blocked, insufficient pump output, air in product, flow and return NTC sensors connected the wrong way round"; the Ultracom2 and Betacom2 add "check the pump speed", and the homeowner page adds a defective expansion vessel and fault in the sensor connections. That last cause — sensors swapped — is why F.23 sometimes appears on a boiler that has just been worked on with nothing mechanically wrong.
Glow-worm's homeowner page calls F.23 "a case for a Glow-worm installer in the first instance, as it can relate to how the boiler is working with the heating system", and gives the owner no checks beyond the general note that a reset can sometimes clear a fault; this page follows that and leaves the pump and sensors to the engineer. On the Ultracom, Flexicom and Ultrapower there is no 23 — their circulation faults are F25 and, on the Flexicom, F24 for a return above 90 °C.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Pump not shifting enough water | Glow-worm's first two causes, "pump blocked" and "insufficient pump output". A rotor seized after a summer idle, a pump on its lowest speed for a large system, or one simply worn out after fifteen years. | Common |
| Air in the boiler | An air pocket at the pump or the heat exchanger stops water reaching one sensor while the other still reads hot. Common after a refill or a repair that involved draining down. | Common |
| Flow and return sensors swapped | Named specifically by Glow-worm: "connected the wrong way round". After a service the two identical clip-on sensors are easy to refit on the wrong pipes, and the spread then reads backwards. | Occasional |
| Blockage in the primary circuit | Sludge in the heat exchanger or a plate exchanger partly blocked slows the water as surely as a tired pump. The homeowner page's "valve, blockage". | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£80–£420
Time on site
1 hour
Sensor refit or purge £80–£130. Pump £250–£420.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Central heating circulating pump
CH-PUMP-15-60£90–£180Plumbing merchant
Price checked 28 September 2026
Magnetic system filter, 22mm
MAG-22£65–£120Plumbing merchant
Price checked 28 September 2026
Glow-worm flow or return temperature sensor (clip-on NTC)
£12–£35Authorised Glow-worm parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Glow-worm fault codes
- F.20Get it checkedThe safety thermal cut-out has tripped and stopped the boiler. Glow-worm's homeowner page lets you check pressure, radiator valves and airlocks first; on Ultracom2 boilers F20 trips at 97 °C.Related: overheat and circulation
- F.83Get it checkedThe burner lit but neither sensor registered any warming — Glow-worm call it dry fire. Low pressure or a sensor off its pipe; the Energy7 guide allows two resets before a 45-minute lockout.Related: overheat and circulation
- F.24Get it checkedThe temperature at the sensor climbed faster than water flowing properly would allow. Glow-worm list the pump, air, low pressure and a stuck non-return valve, and send it to an engineer.Related: overheat and circulation
- F.76Stop — call an engineerThe thermal fuse on the primary heat exchanger has operated or failed. It exists to catch a dry fire the sensors missed, and Glow-worm's test for it is not one an owner performs.Related: overheat and circulation
- F.86Get it checkedThe external safety contact — usually an underfloor heating limit thermostat wired to the boiler — is open, or its link is missing. The boiler will not fire until the contact closes.Related: overheat and circulation
- F.28Get it checkedThree ignition attempts have failed and the boiler has locked out. Glow-worm's guides let you check the gas supply and the condensate pipe and reset three times before calling anyone.Related: same brand
Own a Glow-worm boiler? Save it and its codes come first next time.
Related guides
Common questions about Glow-worm F.23
Can I bleed the radiators and reset?
Bleeding radiators does no harm and air is one of Glow-worm's causes, but the air that matters for F.23 is inside the boiler, which is an engineer's purge. One reset after bleeding is reasonable; if F.23 returns, stop.
How is this different from F.24?
F.23 is the spread between the two sensors too wide; F.24 is one sensor rising too fast. Both come back to circulation, and Glow-worm list nearly the same causes for each.
What does it cost?
Sensors refitted correctly, or a purge, £80–£130. A pump £250–£420. A power flush if the system is sludged £350–£600, which is a system cost rather than a boiler one.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.