Glow-worm F.23 fault codewhat it means and how to fix it

Get it checkedBoilerF.23 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F23 on Ultracom2, Betacom 24a/28a and Betacom2 · no 23 on Ultracom, Flexicom or UltrapowerLast updated

The flow and return temperatures are too far apart, which means water is barely moving through the boiler. Glow-worm point at the pump, air, or the two sensors swapped over.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.23

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.23 means

F.23 is "Safety shutdown: Temperature spread too great (NTC1/NTC2)" in Glow-worm's tables, and the two-digit Ultracom2 and Betacom2 manuals say the same thing in plainer English: "maximum temperature difference reached between return and flow heating — water circulation fault". The flow sensor sits where hot water leaves the heat exchanger and the return sensor where cooler water comes back; the difference between them is a measure of how fast water is moving, and when it opens beyond the board's limit the boiler concludes the water is standing still.

Glow-worm's causes on the current ranges are "pump blocked, insufficient pump output, air in product, flow and return NTC sensors connected the wrong way round"; the Ultracom2 and Betacom2 add "check the pump speed", and the homeowner page adds a defective expansion vessel and fault in the sensor connections. That last cause — sensors swapped — is why F.23 sometimes appears on a boiler that has just been worked on with nothing mechanically wrong.

Glow-worm's homeowner page calls F.23 "a case for a Glow-worm installer in the first instance, as it can relate to how the boiler is working with the heating system", and gives the owner no checks beyond the general note that a reset can sometimes clear a fault; this page follows that and leaves the pump and sensors to the engineer. On the Ultracom, Flexicom and Ultrapower there is no 23 — their circulation faults are F25 and, on the Flexicom, F24 for a return above 90 °C.

What causes it

Causes of the Glow-worm F.23 fault code, most common first
CauseWhat is actually happeningHow likely
Pump not shifting enough waterGlow-worm's first two causes, "pump blocked" and "insufficient pump output". A rotor seized after a summer idle, a pump on its lowest speed for a large system, or one simply worn out after fifteen years.Common
Air in the boilerAn air pocket at the pump or the heat exchanger stops water reaching one sensor while the other still reads hot. Common after a refill or a repair that involved draining down.Common
Flow and return sensors swappedNamed specifically by Glow-worm: "connected the wrong way round". After a service the two identical clip-on sensors are easy to refit on the wrong pipes, and the spread then reads backwards.Occasional
Blockage in the primary circuitSludge in the heat exchanger or a plate exchanger partly blocked slows the water as surely as a tired pump. The homeowner page's "valve, blockage".Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£420

Time on site

1 hour

Sensor refit or purge £80–£130. Pump £250–£420.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Magnetic system filter, 22mm

MAG-22£65–£120Plumbing merchant

Price checked 28 September 2026

Glow-worm flow or return temperature sensor (clip-on NTC)

£12–£35Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.23

Can I bleed the radiators and reset?

Bleeding radiators does no harm and air is one of Glow-worm's causes, but the air that matters for F.23 is inside the boiler, which is an engineer's purge. One reset after bleeding is reasonable; if F.23 returns, stop.

How is this different from F.24?

F.23 is the spread between the two sensors too wide; F.24 is one sensor rising too fast. Both come back to circulation, and Glow-worm list nearly the same causes for each.

What does it cost?

Sensors refitted correctly, or a purge, £80–£130. A pump £250–£420. A power flush if the system is sludged £350–£600, which is a system cost rather than a boiler one.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process