Glow-worm F.24 fault codewhat it means and how to fix it

Get it checkedBoilerF.24 temperature rise too fast on Energy, Ultimate, Easicom, Betacom3/4, Compact, Ultracom2 and Betacom2 · F24 return above 90 °C on Flexicom, Ultracom cxi and the CI rangesLast updated

The temperature at the sensor climbed faster than water flowing properly would allow. Glow-worm list the pump, air, low pressure and a stuck non-return valve, and send it to an engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.24

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.24 means

Glow-worm define F.24 as "Safety shutdown: Temperature rise too fast" on the current ranges, and the Ultracom2 and Betacom2 manuals as "water circulation fault — malfunction of the pump (excessively rapid temperature increase)". The burner has just lit and the flow sensor has jumped several degrees in a few seconds, which can only happen if the water at the sensor is not being replaced. The board stops the burner before F.20 would have to.

Glow-worm's causes are "pump blocked, insufficient pump output, air in product, system pressure too low, non-return valve blocked/incorrectly installed"; the homeowner page adds the sensors and the expansion vessel, and the Ultracom2 manual's check is that the flow and return isolation valves under the boiler are open.

Two of those an owner can look at — pressure and the valves — and Glow-worm's homeowner page nonetheless routes F.24 on a system or combination boiler to a Glow-worm engineer, with only open-vented installations sent to an installer first, so this page carries no steps beyond that. The Flexicom list has a different F24, "central heating return temperature above 90 degrees", and the older cxi and CI-era ranges used 24 the same way, so on those boilers the code is an overheat on the return rather than a fast rise on the flow — the same family of fault seen from the other pipe.

What causes it

Causes of the Glow-worm F.24 fault code, most common first
CauseWhat is actually happeningHow likely
Pump stalled or too slowGlow-worm's first two causes and the Ultracom2's only one. The burner heats water the pump is not moving, and the flow sensor a few inches above the heat exchanger sees it first.Common
Air or low pressureListed together because they behave the same way: a pocket of air at the top of the boiler, or too little water to fill it, and the sensor is measuring steam rather than flow.Common
Isolation valves under the boiler not fully openThe Ultracom2 and Betacom2 manuals put this first. After a service or a filter change the flow or return valve can be left a quarter turn short, and the boiler behaves as if the pump had failed.Occasional
Non-return valve stuck or fitted backwardsGlow-worm's last cause on the current ranges. A check valve in the bypass or the flow that has jammed shut turns the primary circuit into a dead end.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£420

Time on site

1 hour

Valve opened or purge £80–£130. Pump £250–£420. Non-return valve £90–£180.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 28 September 2026

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Magnetic system filter, 22mm

MAG-22£65–£120Plumbing merchant

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.24

Should I check the pressure before calling?

Yes — Glow-worm list "system pressure too low" as a cause, and if it is under 1 bar, topping up as the F.22 page describes and resetting once is a sensible first move. If F.24 returns at good pressure, the fault is circulation and wants an engineer.

Why does Glow-worm treat an open-vented boiler differently?

Because on an open-vented system the pump and the pipework that decide circulation are outside the boiler, so the homeowner page sends those to an installer first. On a combi or system boiler the pump is inside the casing.

Is Flexicom F24 the same thing?

Related but not identical. Flexicom, cxi and CI-era boilers use F24 for a return temperature above 90 °C — an overheat measured on the return — where the current ranges use it for a flow that rose too quickly. Both mean the water is not moving.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?