Skip to content
FaultcodeCheck

myenergi zappi Output Fault

Get it checkedEV chargerzappi v2 and v2.1.Last updated

Code 24: the zappi has measured voltage on its output when the output should have been off. The unit stays off; reset once, and if it repeats it is a call to myenergi.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a registered electrician to look at the myenergi zappi properly.

Get a registered electrician to look at your myenergi zappi ev charger

We do not pass enquiries to a repair firm, so there is no form here. When you book a registered electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What this means

Output Fault, code 24, is the zappi catching itself doing something it should not. myenergi’s definition is that the unit has detected a wrong output voltage, and the example they give is the telling one: a voltage has been detected when it should be off. The zappi measures what is on the cable to the car and compares it with what its relays are supposed to be doing, and when the two disagree it refuses to continue, because the whole point of the relays is that when the charger says off, the car-side pins are dead.

The published action is the standard one, unplug the EV and press and hold the button to reset the unit. This is a code where the persistence clause at the end of the table deserves to be read literally.

A relay that is letting voltage through when open is either sticking or welded, which is the condition code 28 names outright, and a measurement circuit that is reporting voltage that is not there is a protection board fault. Neither is something the reset can mend, so a second 24 in a short period means stop using the charger and contact your supplier or myenergi technical support. It has a twin in code 32, Voltage Mismatch, where the controller and the protection board measure the output differently; 24 is the output being wrong, 32 is the two measurements of it disagreeing.

What causes it

Causes of myenergi zappi Output Fault, most common first
CauseWhat is actually happeningHow likely
A relay letting voltage through when it should be openThe reading the code describes. A sticking or partly welded contact; code 28 is the fully welded case.Common
A transient reading after switchingContacts opening under load can leave a brief voltage on the output that the measurement catches. The single published reset is for this.Occasional
A fault in the output measurement circuitThe zappi reports voltage that is not physically present. Still a hardware fault inside the unit, and still a reason to stop using it.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£400

Time on site

10 minutes

Free under warranty. Otherwise a relay or protection board replacement, or a unit exchange: £150 to £400 with labour.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process