Baxi E.02.07 fault codewhat it means and how to fix it
Low water pressure made permanent on the Baxi 200/400 Combi and Combi 2, after A.02.06 or H.02.06 has been showing. Repressurise to 1 to 1.5 bar and reset; Baxi say you can do it yourself.
Before you start
What E.02.07 means
Baxi's two newest display systems report low pressure in stages, and E.02.07 is the last of them. On the 200 and 400 Combi the sequence is H02 alternating with 06, "low water pressure in the heating circuit", a temporary fault that "will automatically reset once the cause of the fault has been resolved", and then E02 alternating with 07, the same fault as a permanent lockout that needs the RESET button. On the Combi 2 the stages are A.02.06 "low system pressure in heating circuit", with the boiler still running, then H.02.07 "low pressure in heating circuit (permanently)", and the manual's remedy for both is one line: "check the system pressure and restore it, check the pressure of the expansion vessel, check for any system/boiler leaks".
Baxi's Combi 2 quick guide gives the householder the same job in plainer words — "A.02.06 or H.02.07: boiler needs repressurising. All boilers need repressurising occasionally. It's a simple job you can do yourself" — and their repressurising how-to describes the filling loop and the target of 1 to 1.5 bar. The 200/400 user manual lists E02 07 under "low water pressure" and the installer table gives the causes as "water leak on boiler, water leak on system — check boiler, check system, repressurise system".
The point of the staged codes is the same as it was for E118 and E119 on the older Baxis: the sealed system has lost water, and the question is where it went. A top-up once a year is normal; a top-up every week is a leak or a flat expansion vessel, and the Combi 2 manual's mention of the vessel pressure is the clue that a boiler which needs frequent repressurising and occasionally weeps from its relief pipe wants an engineer rather than another turn of the filling loop.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Normal slow loss | Air bled from radiators, tiny weeps at valve glands, and the small amount of water lost through the automatic air vent over months. Baxi's "all boilers need repressurising occasionally". | Common |
| Leak on the system | The 200/400 table's "water leak on system". A radiator valve, a compression joint under a floor, or a corroded radiator. If the pressure falls in days, this is more likely than the boiler. | Common |
| Expansion vessel needs recharging | Named in the Combi 2 remedy: "check the pressure of the expansion vessel". A flat vessel lets the pressure swing from low when cold to the relief valve's limit when hot, discharging water outside each cycle. | Common |
| Leak on the boiler | The 200/400 table's "water leak on boiler". A pump seal, a plate exchanger joint or the pressure relief valve passing. Look for staining under the case and drips from the copper pipe through the wall. | Occasional |
What to try yourself
Read the pressure on the display or gauge. Baxi's how-to gives the cold target as between 1 and 1.5 bar; below about 0.5 bar the boiler stops with this code.
Find the filling loop — a braided hose or a fixed key under the boiler — and open its valves slowly until the pressure reaches 1 to 1.5 bar, then close both. Baxi's repressurising guide and video walk through this.
Reset: RESET for one second on a Combi 2, at least three seconds on a 200 or 400 Combi. H.02.07 on a Combi 2 and H02 06 on a 200/400 clear on their own once the pressure is back.
If you are repressurising more than a couple of times a year, or water drips from the copper pipe outside, stop topping up and call an engineer: the water is going somewhere.
Get a Gas Safe registered engineer to look at your Baxi E.02.07
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£300
Time on site
15 minutes
Repressurising costs nothing. Leak trace from £90. Expansion vessel recharge £80–£120; replacement £200–£300. Pressure relief valve £100–£160.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Expansion vessel (8 litre, sealed system)
EV-8L£35–£85Plumbing merchant
Price checked 28 September 2026
Pressure relief valve, 3 bar
PRV-3B£18–£42Plumbing merchant
Price checked 28 September 2026
Magnetic system filter, 22mm
MAG-22£65–£120Plumbing merchant
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Baxi fault codes
- E118Get it checkedLow water pressure on the digital-display Baxis: 600, 800, Duo-tec 2, Compact, Assure, Megaflo. Defined by Baxi as primary pressure under 0.5 bar. Repressurise and it clears itself.Related: water pressure
- E119Get it checkedLow water pressure on the selector-switch Baxis — Duo-tec Combi HE, Platinum, Megaflo System HE A. Shown as E1 then 19. Repressurise; no reset is needed.Related: water pressure
- E117Get it checkedPrimary water pressure too high, on the Duo-tec 2 and EcoBlue Advance. Usually an overfilled system or a flat expansion vessel. Let some water out and it clears.Related: water pressure
- E430Get it checkedA temporary water-pressure fault on the 600, 800 and Compact family, from Baxi's professional error-code table. If it comes with a crossed flame symbol the pressure self-test has failed.Related: water pressure
- E133Get it checkedBaxi's ignition lockout: "the gas supply has been interrupted, ignition has failed or the flame has not been detected". Check the gas is on, reset once. If it returns, stop.Related: same brand
- E.04.10Get it checkedIgnition failure on the Baxi 200/400 Combi and every Combi 2: the burner would not light after its allowed attempts. Baxi's own quick guide names it the frozen-condensate code you can fix yourself.Related: same brand
Own a Baxi boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.