Primary water pressure too high, on the Duo-tec 2 and EcoBlue Advance. Usually an overfilled system or a flat expansion vessel. Let some water out and it clears.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

When is the pressure high?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

It is high cold and hot

Too much water in the system, or the filling loop is passing.

Close the loop valves, then bleed down to 1 to 1.5 bar cold.

Fine cold, climbs to the red when hot

The expansion vessel has lost its charge. Expect the relief valve to be dripping outside.

Recharge or replace the vessel; check the relief valve reseats.

What E117 means

E117 is the opposite of E118, and Baxi print it on fewer boilers. The 2012 Duo-tec 2 Combi GA user guide lists "117 — Primary System Water Pressure Too High" and marks it with the R symbol; the EcoBlue Advance Combi user guide has the same entry and adds that "Error Codes 117 and 118 can be reset by restoring the correct system pressure as described in 7.3", so there is no button to press.

The 600, 800 and Compact manuals do not print it, though Baxi's professional error-code table lists E430 as a "water pressure temporary fault" for that family, which is a different code. High pressure on a sealed system has two ordinary explanations. Either somebody filled it too far — the gauge should read 1 to 1.5 bar cold, and a system filled to 2 bar cold will be near 3 bar hot — or the expansion vessel has lost its air charge and can no longer absorb the expansion, so the pressure climbs steeply on every heat-up and the relief valve lifts at 3 bar.

A filling loop left open is the third, and it is worth checking both valves on the braided hose before assuming anything else. The relief valve is a one-way trip: once it has lifted it often does not reseat cleanly, and a boiler that shows E117 hot and E118 cold within the same week has almost always got a valve dribbling outside and a vessel that needs recharging.

What causes it

Causes of the Baxi E117 fault code, most common first
CauseWhat is actually happeningHow likely
System overfilledTopped up hot, or taken well past 1.5 bar cold. Baxi's user guides set 1 to 1.5 bar as the cold target precisely because the pressure rises as the water heats.Common
Expansion vessel lost its chargeWithout a cushion of air the pressure rises sharply as the water expands, often into the red on the gauge within minutes of firing, and the relief valve discharges outside.Common
Filling loop valve left openMains pressure feeding the heating circuit continuously. The gauge sits high all the time, hot or cold, and the relief valve runs constantly.Occasional
Plate heat exchanger letting mains water acrossOn a combi a split in the plate exchanger lets cold mains into the heating side. Pressure creeps up with no filling loop open and no obvious cause; the heat exchanger is the repair.Rare

What to try yourself

  1. Check both valves on the filling loop are fully closed. If one is even slightly open, close it and see whether the gauge stops climbing.

  2. With the system cold, bleed a radiator until the gauge falls to between 1 and 1.5 bar. Use a radiator key and a cloth; a small amount of water will come out after the air.

    Do not bleed a hot system. The water is scalding and the reading will be wrong once it cools.
  3. Run the heating and watch the gauge. On a healthy system it rises by a fraction of a bar and steadies. If it heads for 3 bar the expansion vessel needs recharging and that is an engineer job.

Get a Gas Safe registered engineer to look at your Baxi E117

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£300

Time on site

15 minutes

Free to bleed down. Expansion vessel recharge from £80, replacement £150–£300. Pressure relief valve £90–£160.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 28 September 2026

Pressure relief valve, 3 bar

PRV-3B£18–£42Plumbing merchant

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?