Baxi E117 fault codewhat it means and how to fix it
Primary water pressure too high, on the Duo-tec 2 and EcoBlue Advance. Usually an overfilled system or a flat expansion vessel. Let some water out and it clears.
Take care
When is the pressure high?
The right answer depends on what you can see. Pick the one that matches.
Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.
It is high cold and hot
Too much water in the system, or the filling loop is passing.
Close the loop valves, then bleed down to 1 to 1.5 bar cold.
Fine cold, climbs to the red when hot
The expansion vessel has lost its charge. Expect the relief valve to be dripping outside.
Recharge or replace the vessel; check the relief valve reseats.
What E117 means
E117 is the opposite of E118, and Baxi print it on fewer boilers. The 2012 Duo-tec 2 Combi GA user guide lists "117 — Primary System Water Pressure Too High" and marks it with the R symbol; the EcoBlue Advance Combi user guide has the same entry and adds that "Error Codes 117 and 118 can be reset by restoring the correct system pressure as described in 7.3", so there is no button to press.
The 600, 800 and Compact manuals do not print it, though Baxi's professional error-code table lists E430 as a "water pressure temporary fault" for that family, which is a different code. High pressure on a sealed system has two ordinary explanations. Either somebody filled it too far — the gauge should read 1 to 1.5 bar cold, and a system filled to 2 bar cold will be near 3 bar hot — or the expansion vessel has lost its air charge and can no longer absorb the expansion, so the pressure climbs steeply on every heat-up and the relief valve lifts at 3 bar.
A filling loop left open is the third, and it is worth checking both valves on the braided hose before assuming anything else. The relief valve is a one-way trip: once it has lifted it often does not reseat cleanly, and a boiler that shows E117 hot and E118 cold within the same week has almost always got a valve dribbling outside and a vessel that needs recharging.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| System overfilled | Topped up hot, or taken well past 1.5 bar cold. Baxi's user guides set 1 to 1.5 bar as the cold target precisely because the pressure rises as the water heats. | Common |
| Expansion vessel lost its charge | Without a cushion of air the pressure rises sharply as the water expands, often into the red on the gauge within minutes of firing, and the relief valve discharges outside. | Common |
| Filling loop valve left open | Mains pressure feeding the heating circuit continuously. The gauge sits high all the time, hot or cold, and the relief valve runs constantly. | Occasional |
| Plate heat exchanger letting mains water across | On a combi a split in the plate exchanger lets cold mains into the heating side. Pressure creeps up with no filling loop open and no obvious cause; the heat exchanger is the repair. | Rare |
What to try yourself
Check both valves on the filling loop are fully closed. If one is even slightly open, close it and see whether the gauge stops climbing.
With the system cold, bleed a radiator until the gauge falls to between 1 and 1.5 bar. Use a radiator key and a cloth; a small amount of water will come out after the air.
Do not bleed a hot system. The water is scalding and the reading will be wrong once it cools.Run the heating and watch the gauge. On a healthy system it rises by a fraction of a bar and steadies. If it heads for 3 bar the expansion vessel needs recharging and that is an engineer job.
Get a Gas Safe registered engineer to look at your Baxi E117
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£300
Time on site
15 minutes
Free to bleed down. Expansion vessel recharge from £80, replacement £150–£300. Pressure relief valve £90–£160.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Expansion vessel (8 litre, sealed system)
EV-8L£35–£85Plumbing merchant
Price checked 28 September 2026
Pressure relief valve, 3 bar
PRV-3B£18–£42Plumbing merchant
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Baxi fault codes
- E118Get it checkedLow water pressure on the digital-display Baxis: 600, 800, Duo-tec 2, Compact, Assure, Megaflo. Defined by Baxi as primary pressure under 0.5 bar. Repressurise and it clears itself.Related: water pressure
- E119Get it checkedLow water pressure on the selector-switch Baxis — Duo-tec Combi HE, Platinum, Megaflo System HE A. Shown as E1 then 19. Repressurise; no reset is needed.Related: water pressure
- E.02.07Usually simple to fixLow water pressure made permanent on the Baxi 200/400 Combi and Combi 2, after A.02.06 or H.02.06 has been showing. Repressurise to 1 to 1.5 bar and reset; Baxi say you can do it yourself.Related: water pressure
- E430Get it checkedA temporary water-pressure fault on the 600, 800 and Compact family, from Baxi's professional error-code table. If it comes with a crossed flame symbol the pressure self-test has failed.Related: water pressure
- E133Get it checkedBaxi's ignition lockout: "the gas supply has been interrupted, ignition has failed or the flame has not been detected". Check the gas is on, reset once. If it returns, stop.Related: same brand
- E.04.10Get it checkedIgnition failure on the Baxi 200/400 Combi and every Combi 2: the burner would not light after its allowed attempts. Baxi's own quick guide names it the frozen-condensate code you can fix yourself.Related: same brand
Own a Baxi boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.