Baxi E118 fault codewhat it means and how to fix it

Get it checkedBoilerDigital display with a spanner or R symbol and a Reset button: Baxi 600 and 800 Combi and System, Duo-tec 2 Combi GA, Duo-tec Compact, Platinum Compact, Megaflo Compact and Megaflo System, Assure Combi and System, 636, EcoBlue Advance and Plus. Selector-switch boilers show E119 for the same condition.Last updated

Low water pressure on the digital-display Baxis: 600, 800, Duo-tec 2, Compact, Assure, Megaflo. Defined by Baxi as primary pressure under 0.5 bar. Repressurise and it clears itself.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

What does the pressure gauge on the front of the boiler read?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

It reads below 0.5 bar, in the red

The code is telling the truth. Repressurise and it will clear.

Follow the steps above. If it is back within a month, ask for a leak check and the expansion vessel charge.

It reads 1 bar or more and E118 is still showing

The boiler cannot see the pressure the gauge is showing. On the 600 and 800 that points at the hydraulic pressure switch or its wiring to connector X22.

An engineer job; it is a quick one, and the switch is a stocked Baxi part.

It keeps coming back every few days

Either the expansion vessel is flat or something is leaking faster than it should.

Stop topping up and get the vessel charge and the system pressure-tested.

What E118 means

E118 is the low-pressure code on every Baxi with a digital display and a Reset button — the 600 and 800 Combi and System, the Duo-tec 2 Combi GA, the Duo-tec, Platinum and Megaflo Compact, the Assure and the later Megaflo System. The 600 Combi installation manual defines it in one line: "118 is displayed when the primary water pressure is less than 0.5 bar", and the table entry is "Primary system water pressure too low".

The user guide for the same boiler puts E118 in its problems-and-solutions table with the remedy "Re-pressurise the system" and gives the working range as 1 to 1.5 bar cold on the dial. That is the whole of the manufacturer's position: the sealed circuit has lost water, the boiler will not fire a heat exchanger it cannot be sure is full, and the code goes when the pressure comes back.

What the manual adds for the engineer is worth knowing. The component behind the code is a hydraulic pressure switch on the 600 and 800 (Baxi part 5114748), and the fault-finding flow for E118 checks first that the system really is below 0.5 bar, then the switch wiring and a 5 V feed at connector X22 on the PCB, then replaces the switch. So a boiler showing E118 with a healthy gauge reading has a switch or wiring problem, not a leak. If you own an older selector-switch Baxi the same fault is E119, and that page explains the difference. The EcoBlue Advance user guide adds that "Error Codes 117 and 118 can be reset by restoring the correct system pressure" without pressing anything.

What causes it

Causes of the Baxi E118 fault code, most common first
CauseWhat is actually happeningHow likely
Pressure has genuinely fallen below 0.5 barA sealed system does not use water, so the loss is a leak somewhere: a radiator valve gland, a joint under a floor, the pressure relief valve passing, or a slow weep at the boiler's own automatic air vent.Common
Expansion vessel has lost its chargeWhen the vessel's air side is flat the pressure swings hard with temperature and the relief valve lifts on every hot cycle, discharging water outside. The gauge then reads low every few days for no visible reason.Common
Hydraulic pressure switch or its wiringThe 600 Combi fault-finding flow goes here when the system is above 0.5 bar and E118 persists: check the wiring and the 5 V DC feed at PCB connector X22, then replace the switch. The boiler is reporting a pressure it is not actually seeing.Occasional
Air trapped after recent workA system refilled after a radiator change can read fine and then drop as air migrates to the top and is bled off. Baxi's own user guide says the de-aeration function must be repeated after any partial drain.Occasional

What to try yourself

  1. Read the pressure gauge on the front of the boiler with the system cold. Baxi's user guide wants it between 1 and 1.5 bar cold; below 0.5 bar is where E118 appears.

  2. Find the filling loop. On a 600 or 800 it is usually a braided hose with a valve at each end under the boiler, though some installations use a pair of taps on the pipework or an internal keyed link.

  3. Open both valves slowly and watch the gauge climb. Stop at 1 to 1.5 bar. Close both valves fully.

    Do not take it past 2.5 bar. Baxi's pressure relief valve lifts at 3 bar and will dump the excess outside, and a system that has been overfilled cold will be well over when hot.
  4. E118 clears itself once the pressure is back. If the boiler still shows a code, check it is E118 and not something else, then press Reset for one to three seconds.

  5. Bleed any radiators that are cold at the top, then check the gauge again and top up if needed. Note the date; if you are back here within a few weeks there is a leak or a flat expansion vessel to find.

Get a Gas Safe registered engineer to look at your Baxi E118

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£300

Time on site

10 minutes

Free to repressurise. Leak trace from about £90. Hydraulic pressure switch (Baxi 5114748) fitted around £120–£180. Expansion vessel recharge or replacement £120–£300.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 28 September 2026

Pressure relief valve, 3 bar

PRV-3B£18–£42Plumbing merchant

Price checked 28 September 2026

Baxi / Potterton / Main hydraulic pressure switch (600, 800, Assure, Eco Compact)

5114748£40–£90Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Baxi E118

Is E118 the same as E119?

Same fault, different generation. Baxi boilers with the rotary selector switch and a two-character display (Duo-tec Combi HE, Platinum) report low pressure as E119; boilers with the digital display and a Reset button (600, 800, Duo-tec 2, Compact, Assure, Megaflo) report it as E118. Both are defined in the manuals as primary pressure below 0.5 bar. Neither is a typo for the other.

Do I need to press Reset after repressurising?

Usually not. E118 is one of the codes Baxi mark with the R symbol, but the manuals say it clears when the pressure is restored, and the EcoBlue Advance guide says so explicitly for 117 and 118. If a code remains after the gauge is back above 1 bar, read it again — it may be a different one.

What pressure should a Baxi 600 or 800 run at?

The user guide gives 1 to 1.5 bar with the system cold. It will read higher when hot, which is normal. Set it cold, not after the heating has been on.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?