Baxi E119 fault codewhat it means and how to fix it

Get it checkedBoilerDuo-tec and 600 seriesLast reviewed

System pressure has fallen below the level the boiler will operate at. Refilling to 1.2 bar and resetting usually clears it in a few minutes.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

How quickly does the pressure fall after you fill it?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

It holds for months

Normal. Top up and carry on; once or twice a year is expected.

It falls again within a few weeks

A slow leak or a tired expansion vessel. Worth diagnosing before the constant refilling corrodes the system.

Ask for a pressure test and for the expansion vessel charge to be checked.

It falls within hours

A real leak, and possibly one causing damage you have not found.

Stop refilling, turn the boiler off, and get someone out.

What E119 means

E119 is Baxi reporting low water pressure in the sealed heating circuit. Below roughly 0.5 bar the boiler stops the burner, because heating a heat exchanger that does not have enough water flowing through it wrecks it quickly. The lockout is the appliance protecting itself and it is doing the right thing. What matters is the reason the pressure fell, because a sealed system does not consume water. Somewhere it is escaping: a weeping valve, a joint under a floor, an expansion vessel that has lost its charge, or a pressure relief valve holding slightly open on a bit of debris.

What causes it

Causes of the Baxi E119 fault code, most common first
CauseWhat is actually happeningHow likely
Corroded radiator letting goA pinhole through a rusted panel, often on a towel rail or a radiator in a bathroom. Frequently marked by a rust-coloured crust rather than an obvious puddle.Common
Valve gland weepingThe packing behind a radiator valve handle dries and seeps. Usually cured by a quarter turn on the gland nut rather than a new valve.Common
Vessel charge goneBaxi appliances often carry the vessel behind the heat exchanger, which makes it awkward to reach and correspondingly likely to have been skipped at every service so far.Occasional
Automatic air vent leakingThe small brass vent on top of the pump or manifold can pass water instead of air once the seal hardens. It drips inside the case rather than outside, so nobody sees it.Occasional

What to try yourself

  1. Take the reading cold. On a Duo-tec the pressure appears on the LCD behind the front flap rather than on a separate dial.

  2. Look underneath for the filling loop. Baxi installations vary — some have the braided hose, others a pair of chrome taps on the pipework, and a few use an internal keyed link.

  3. Open both ends slowly. You should hear water moving. Bring it to 1.2 bar and no further.

    Overfilling is not harmless on an older system. Pushing past 2.5 bar cold can start a weep at a joint that had been perfectly sound.
  4. Close both ends firmly and check they are shut by feeling whether the hose has gone quiet and cool.

  5. Record the date. Two top-ups a year is tolerable; four is a leak that will cost less to find now than to live with.

Get a Gas Safe registered engineer to look at your Baxi E119

Gas Safe Register engineers only. No obligation.

What it costs to fix

Typical repair cost

£0–£450

Time on site

10 minutes

Free to top up. Leak trace £90–£160. Expansion vessel £150–£280.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 5 August 2026

Pressure relief valve, 3 bar

PRV-3B£18–£42Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Common questions about Baxi E119

What pressure should a Baxi boiler be at?

1.0 to 1.5 bar cold, with 1.2 bar the usual target. Higher when hot is normal and expected. Always set it with the system cold, not after the heating has been running.

Is E119 the same as E118?

They are closely related — both concern system pressure — but they are separate conditions and the boiler distinguishes between them. Quote the exact number you can see rather than the one you half remember, because it changes what the engineer checks first.

Can I fill it while the boiler is hot?

Better not to. Water expands as it heats, so filling to 1.2 bar hot means it will sit too low once cold. Let it cool, then fill.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process