Skip to content
FaultcodeCheck

Baxi E430 fault codewhat it means and how to fix it

Get it checkedBoilerDigital display, the 600 and 800 Combi and System, Duo-tec and Platinum Compact, Megaflo Compact and System, Assure. Listed on Baxi's professional error-code page for those ranges; not in their printed manuals.Last updated

A temporary water-pressure fault on the 600, 800 and Compact family, from Baxi's professional error-code table. If it comes with a crossed flame symbol the pressure self-test has failed.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

Get a Gas Safe registered engineer to look at your Baxi E430

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Is there a crossed-out flame symbol with it?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

Just E430, no flame symbol

A temporary pressure fault. Check the gauge and top up if it is under 1 bar; it may clear on its own.

If it persists with the gauge above 1 bar, book an engineer for the pressure switch and wiring.

E430 with a crossed flame

Baxi list this as "water pressure test failed" — the boiler ran its check and the reading did not respond as it should.

Engineer visit. It is a diagnostic rather than a repair you can do from the front panel.

What E430 means

E430 is on Baxi's professional error-code page but not in the printed 600, 800 or Compact tables, which is why a reader who has just been through the manual has not found it. Baxi give two entries: "E430 / 166 — Water pressure temporary fault", and "E430 / 166 + Flame 'crossed' — Water pressure test failed". The "/ 166" is the older two-digit rendering of the same fault on boards that could not show a number above 255, and it is worth knowing only so that a 166 in an old service note does not send you looking for a different problem.

Read alongside E118, the shape is clear enough. E118 is the boiler saying the pressure is under 0.5 bar; E430 is the boiler saying it could not get a sensible reading, or that the reading did not behave as expected when the pump ran. The first thing to do is what you would do for E118 — check the gauge, top up if it is low, and see whether the code clears — because a system right at the bottom of the range can produce either.

If the gauge is fine and E430 stays, the hydraulic pressure switch, its wiring to the PCB, or the board itself is where an engineer will look, and the 600 Combi fault-finding flow for the pressure circuit (5 V DC at connector X22, then the switch) is the sequence they will follow. Baxi do not print a homeowner action for E430; the user guides say a code not in the table means "contact Baxi Customer Support".

What causes it

Causes of the Baxi E430 fault code, most common first
CauseWhat is actually happeningHow likely
Pressure at the bottom of the rangeA system sitting around 0.5 to 0.7 bar can give the board an inconsistent reading as the pump starts and the pressure dips. Topping up to 1 to 1.5 bar removes the ambiguity.Common
Pressure switch wiring or connectorA loose or corroded connection at the switch or at PCB connector X22 gives the board a signal that comes and goes, which is what a "temporary fault" reads as from the outside.Common
Hydraulic pressure switch failingThe switch is a mechanical device in the water circuit and can stick or chatter. The 600 and 800 use Baxi part 5114748; the fault-finding flow ends with its replacement.Occasional
PCB not reading the inputIf the 5 V feed to the switch is missing the board cannot see the switch at all. Baxi's flow says check for approximately 5 V DC between green and black at X22 before condemning anything else.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£0–£250

Time on site

45 minutes

Free if topping up clears it. Hydraulic pressure switch (Baxi 5114748) fitted around £120–£180. A PCB, if the 5 V feed is missing, £250 or more.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main hydraulic pressure switch (600, 800, Assure, Eco Compact)

5114748£40–£90Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi / Potterton / Main main PCB

£150–£320Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer support portal
  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?