Baxi E15 fault codewhat it means and how to fix it

Get it checkedBoilerDigital display: Baxi 600 and 800 Combi and System, Duo-tec 2 Combi GA, Duo-tec, Platinum and Megaflo Compact, Megaflo System, Assure. Not in the selector-switch tables.Last updated

Gas valve fault on the digital-display Baxis — "gas valve command fault" on Baxi's professional page. One reset is allowed; after that it is the valve or the board.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

Get a Gas Safe registered engineer to look at your Baxi E15

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What E15 means

E15 is the second entry in the Baxi digital-display table, "Gas valve fault", and Baxi's professional page refines it to "Gas valve command fault": the board sent a command to the valve and did not get the response it expected. It differs from E09 by a step. E09 is the cable between board and valve testing as open; E15 is the cable apparently intact but the valve not doing what it is told. The 600 and 800 manuals include E15 in the sentence "09 followed by 15 or 384 indicates possible faulty components", allow it to be relit by "pressing the Reset button for 1 to 3 seconds", and in the fault-finding flow send the engineer down the same path as E09: check all PCB connections, then replace the PCB.

In practice the order of suspicion is the valve first, because a gas valve on a boiler ten years old has done several hundred thousand cycles and its solenoid or the modulating coil can fail while the cable is perfectly good, then the board.

On the 600 and 800 the valve is Baxi part 7683968, a sealed unit that is replaced complete and set up with a combustion analyser afterwards. The boiler will not attempt ignition while E15 is showing, so the code is safe in the sense that no gas is passing; it is not a code to clear repeatedly, because each reset asks the valve to try again and a valve that is sticking rather than failed outright may one day answer late instead of not at all. Selector-switch Baxis do not print E15.

What causes it

Causes of the Baxi E15 fault code, most common first
CauseWhat is actually happeningHow likely
Gas valve solenoid or modulating coil failedThe valve receives the command and does not move, or reports a position the board rejects. Replaced as a complete unit and re-commissioned with a combustion analyser.Common
Connector or cable intermittentA connection good enough to pass the continuity check but not to carry the drive current. Baxi's instruction to "check all PCB connections" catches this before any part is bought.Occasional
PCB drive circuitIf the valve and its cable test good, Baxi's flow ends at the board. The drive and monitoring for the valve is on the PCB and is not repairable separately.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£450

Time on site

1 hour

Connection repair £80–£150. Gas valve (Baxi 7683968) fitted and set up £280–£450. PCB £250–£400.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main gas valve

7683968£120–£240Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi / Potterton / Main main PCB

£150–£320Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Baxi boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process