Skip to content
FaultcodeCheck

Baxi E384 fault codewhat it means and how to fix it

Get it checkedBoilerDigital display with an R symbol: Baxi 600 and 800 Combi and System, Duo-tec 2 Combi GA, Duo-tec, Platinum and Megaflo Compact, Megaflo System, Assure, EcoBlue Advance. Older boards showed it as 164.Last updated

False flame: the board sees a flame signal when the burner should be off. Baxi's manuals point at the electrode, its lead and the PCB. Resettable, but not a fault to live with.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

Get a Gas Safe registered engineer to look at your Baxi E384

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What E384 means

E384 is "False flame" in every Baxi digital-display table, and "False flame (parasitic flame)" on Baxi's professional page, where it is paired with the older two-digit rendering 164. The board monitors the flame-sensing electrode continuously, and if it registers a flame current at a moment when no flame should exist — before ignition, or after the valve has closed — it stops and shows E384 rather than open the gas valve onto what it thinks is a fire already burning.

The 600 and 800 manuals list it among the codes that can be relit by "pressing the Reset button for 1 to 3 seconds", and their fault-finding flow says that "if 09, 15, 110 or 384 is flashing or re-occurs regularly, check all PCB connections. If this has no effect replace the PCB."

A flame signal without a flame is nearly always electrical: moisture or deposit on the electrode insulator giving a leakage path to earth, a chafed or damp electrode lead, an earth fault on the appliance, or the board's own flame-detection circuit. It can also be a flame that really is still burning — a gas valve that is not closing fully and leaving a small flame at the burner — which is the one cause that is not electrical and the reason the boiler treats the condition seriously. Baxi print E384 on the digital-display boilers only; the selector-switch generation has no equivalent code.

What causes it

Causes of the Baxi E384 fault code, most common first
CauseWhat is actually happeningHow likely
Electrode insulator trackingCondensation or combustion deposit on the ceramic gives the sensing current a path to earth. The board reads a small current and calls it a flame. Cleaning or replacing the electrode (Baxi 7686344 on the 600 and 800) is the fix.Common
Electrode lead or connectionA lead resting against the case, a damp connector, or a cracked boot. Baxi's ignition flow checks the electrode connection and lead before the board.Common
PCB flame-detection circuitBaxi say to check all PCB connections and then replace the PCB if E384 recurs regularly. The detection circuit is on the board and cannot be repaired separately.Occasional
Gas valve not closing fullyA genuine residual flame after the valve should have shut. Rare, but it is the case that justifies the boiler locking out rather than ignoring the signal, and it is a gas valve replacement.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£110–£400

Time on site

45 minutes

Electrode (Baxi 7686344) fitted £110–£180. Lead or connector repair within a service call. PCB £250–£400.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main detection and spark ignition electrode

7686344£25–£60Authorised Baxi parts distributor

Price checked 28 September 2026

Baxi / Potterton / Main main PCB

£150–£320Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Baxi boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process